Plumbing connection using one or more generators with direct pump
9
1
Gas inlet
2
System delivery
3
System return
4
Condensate drain
5
Blind flanges
Plumbing circuit examples
Key of examples
I
ISPESL safety devices
D
Hydraulic separator
42
DHW temperature sensor (not supplied)
72
Room thermostat (not supplied)
72b Room thermostat (not supplied)
95
3-way valve - with spring return: at rest on DHW
side (not supplied)
130 Hot water tank circulating pump (not supplied)
138 External probe (not supplied)
Parameters
Each system requires a different parametrisation.Follow the procedure for accessing the two menus, given below; for
the parameters to be modified, refer to the tables given next to the plumbing diagrams.
"Service Menu"
Press the Reset button for 10 seconds to access the card Service Menu.
Press the Heating buttons to select "tS", "In", "Hi" or "rE"". "tS" means Transparent Parameters Menu, "In" Information
Menu, "Hi" History Menu, and "rE" History Menu Reset. Select "tS" and press the Reset button.
The card has 29 transparent parameters also modifiable from Remote Control (Service Menu).
Press the Heating buttons to scroll the list of parameters in increasing or decreasing order. Press the DHW buttons to
modify the value of a parameter: the change will be automatically saved.
Press the Reset button to return to the Service Menu. Press the Reset button for 10 seconds to exit the card Service
Menu.
"System Type Menu"
Press the Summer/Winter button for 10 seconds to access the card System Type Menu.
The card has 21 transparent parameters.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing order. Press the DHW buttons to
modify the value of a parameter: the change will be automatically saved.
Press the Summer/Winter button for 10 seconds to exit the card System Type Menu.
EN
8
fig. 18
cod. 3540H322 - 09/2008 (Rev. 01)
8
6
6
Connection side
7
Flanges with joining section
8
Seals
9
Delivery/return connection
139 Remote control (not supplied)
298 Cascade temperature sensor (not supplied)
306 Heating system circulating pump (not supplied)
307 Heating system second circulating pump (not
supplied)
SM Delivery probe (supplied with kit FZ4)
TS
Safety thermostat (not supplied)
PZ
Zone pump (not supplied)
FZ4 Zone regulator
1
1
2
2
3
3
7
4
61