KitchenAid 720-0787D Manual De Uso página 25

Asador autónomo para exteriores
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Prepare the Grill for Lighting
1.
Open the hood completely. Do not light burners with the
hood closed.
2.
Make sure control knobs are turned to OFF. The grease
cup must be in place.
A. Grease cup
Turn the Gas Supply On
1.
For using a 20 lb LP gas fuel tank: Slowly open the tank
valve.
NOTE: If flow limiting device activates, your grill may not
light. If your grill does light, the flames will be low and will not
heat properly. Turn tank valve and all control knobs off and
wait 30 seconds. After shutting off the tank, very slowly open
wait 30 seconds. After shutting off the tank, very slowly open
tank valve and wait 5 seconds before lighting.
2.
For outdoor grills using gas supply source other than a
20 lb LP gas fuel tank:
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
Lighting the Main Burner
1.
Open the hood completely. Do not light burners with the
hood closed.
2.
Do not lean over the grill.
3.
Select the burner you want to light. Push in and turn the
grill burner control knob to IGNITE/HIGH, while continuing
to hold it in.
4.
You will hear the "snapping" sound of the spark. When
burner is lit, release the knob. Turn knob to desired setting.
5.
Repeat for each of the other burners as needed.
IMPORTANT: If burner does not light immediately, turn the
burner knob to OFF and wait 5 minutes before relighting.
Manually Lighting Main Burners
y
g
1.
Open the hood completely. Do not light burners with
hood closed.
2.
Do not lean over the grill.
3.
Remove the manual lighting rod from the inside of the
cabinet door (see following illustration) and attach a
match to the split ring.
A
4
4.
Strike the match to light it.
Strike the match to light it
5.
Guide the lit match between the grill grate.
6.
Push in and turn the burner knob to IGNITE/HIGH for the
burner closest to the lit match. The burner will light
immediately. When burner is lit, turn knob to desired
setting.
setting
7.
Repeat steps 2 trough 6 for each main burner.
8.
Remove match and replace manual lighting extension
inside the cabinet door.
IMPORTANT:
If burner does not light immediately, turn the burner knob to
OFF and wait 5 minutes before relighting.
If any burners do not light after attempting to light them
manually, contact the Customer Service Center. See the
" Assistance or Service" section.
g
25
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

730-0787d

Tabla de contenido