WARNING: the anti-tear rubber element must never be completely
compressed. Scrupulously check that the rubber does not become
totally compressed during operation.
6) ELECTRICAL INSTALLATION SET-UP (Fig.16)
M)
Actuator
Ft)
Transmitter photocell
Fr)
Receiver photocells
T)
1-2-4 channel transmitter.
Arrange for the connections of accessories and safety and control devices
to reach the motor unit, keeping the mains voltage connections clearly
separate from the extra low safety voltage connections (24V) by means of
the appropriate cable holder (fig. 8 ref. 5P1).
Proceed to connection following the indications given in the wiring diagram.
The cables for connecting the accessories must be protected by a raceway
(fig. 8 ref. 5C1).
7) VENERE Control panel (Fig.17)
Supply to accessories: ..................................................24V~ (180mA max)
.............................................................24V~ Vsafe VENERE (180mA max)
Torque limiter setting:..............................................on closing and opening
Automatic closing time:.........................................................from 3 to 120s
Blinker connection:..............................................................24V~ max 25W
Service light switching-on time:..............................................................90s
Incorporated rolling-code radio receiver:..................frequency 433.92 MHz
Coding:.......................................................................rolling-code algorithm
No. combinations:...........................................................................4 milliard
Antenna impedance:............................................................50Ohm (RG58)
Max no. radio controls to be memorised:..................................................10
Slow-down distance:................closing: ~24 cm ............... opening: ~24 cm
Fuses:......................................................................................see figure 17
7.1) Terminal board connections (Fig.17)
WARNINGS - For wiring and installation operations, refer to the current
standards and good technical principles.
The wires supplied with extra low safety voltage (24V) must be kept physi-
cally separate from the low voltage wires, or else they must be provided with
adequate additional insulation of at least 1mm.
The wires must be clamped by an extra fastener near the terminals, for
example by bands.
TERMINAL
DESCRIPTION
JP6
transformer wiring
JP7
motor wiring
1-2
Antenna input for integrated radio-receiver board
(1: BRAID. 2: SIGNAL)
3-4
START input (N.O.)
3-5
STOP input (N.C.) If not used, leave the jumper inserted.
3-6
PHOTOCELL input (N.C.) If not used, leave the jumper
inserted.
3-7
FAULT input (N.O.)
Input for photocells provided with checking N.O. contact
8-9
24 V~ output for blinking light (25 W max)
10-11
24V~ 180mA max output – power supply for photocells
or other devices
12-13
24V~Vsafe 180mA max output – power supply for checking
photocell transmitters.
7.2) LED (Fig.17)
The led functions are as follows:
"RADIO":Incorporated radio-receiver led.
"SET":
Limit device setting led - power ON.
7.3) DIP-SWITCH SELECTION (Fig.17)
DIP1) IBL – Locks impulses.
ON:
During the opening phase, does not accept START commands.
OFF: During the opening phase, accepts START commands.
DIP2) TEST PHOT
ON:
Enables photocell checking (5-connector photocells must be used
- see Fig.17A-).
OFF: Disables photocell checking.
INSTALLATION MANUAL
7.4) TRIMMER SETTING (Fig.17)
TCA
Sets the automatic closing time, after which the gate closes automatically
(can be set from 3 to 120 sec). If the trimmer is turned all the way, the TCA
is disabled.
OPENING TORQUE
Sets the ampere-stop sensitivity on opening.
CLOSING TORQUE
Sets the ampere-stop sensitivity on closing.
NOTE: In case of obstacle detection, the Ampere-stop function halts
the leaf movement, reverses the motion for 1 sec. and stays in the
STOP state.
WARNING: check that the impact force value measured at the
points established by the EN 12445 standard is lower than that
specified in the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or ani-
mals, or damage to things.
7.5) BUTTONS
"UP":
"DOWN": limit device setting and closing command.
"OK":
8) LIMIT DEVICE SETTING (Fig.18)
1) Simultaneously press the "UP" and "DOWN" keys for 5 seconds. The
"SET" led blinks to indicate that the limit device setting is activated.
2) Bring the leaf to the required closing position, using the "UP" and "DOWN"
buttons on the control unit, and keeping in mind that the "DOWN" button
closes the leaf, while the "UP" button opens the leaf.
3) As soon as the leaf reaches the required closing position, press the "OK"
button in order to memorise the limit device closing position. The "SET"
led confirms data storage by blinking for 1 second.
4) Bring the leaf to the required opening position, using the "UP"and "DOWN"
buttons on the control unit, and keeping in mind that the "DOWN" button
closes the leaf, while the "UP" button opens the leaf.
5) As soon as the leaf reaches the required opening position, press the
"OK" button in order to memorise the limit device opening position. The
"SET" led confirms data storage by blinking for 1 second and then lits up
again.
6) Correctly position the "carriage lock" against the carriage (fig.18 ref.6 A-B).
NOTE 1: These manoeuvres are carried out in "hold-to-run" mode at reduced
speed and with no safety devices activated.
NOTE 2: In case of errors, the "SET" led remains off on for 5 seconds.
9) OPENING / CLOSING TORQUE AUTOSETTING (Fig.19)
1) After reaching the closing end-of-stroke position, press the "UP" button
for 5 seconds.
2) The "SET" led blinks rapidly and the leaf starts to open until it reaches
the opening end-of-stroke.
3) 3 second down time.
4) The "SET" led blinks rapidly and the leaf starts to close until it reaches
the closing end-of-stroke
5) After completing the autoset adjust the opening/closing torque trimmers
so as to obtain the desired sensitivity to the obstacle.
Any input activation (START, RADIO TRANSMITTER, STOP, PHOTOCELL)
during autosetting will annul the autoset in progress.
10) INTEGRATED RECEIVER
Transmitter versions which can be used:
all Rolling Code transmitters compatible with
10.1)ANTENNA INSTALLATION
Use an antenna tuned to 433MHz.
For Antenna-Receiver connection, use RG8 coaxial cable.
The presence of metallic masses next to the antenna can interfere with radio
reception. In case of insufficient transmitter range, move the antenna to a
more suitable position.
10.2) MANUAL TRANSMITTER PROGRAMMING (Fig.20)
1) Press the "OK" button on the control unit.
2) When the "RADIO" LED blinks, press the transmitter P1 hidden key, and
the "RADIO" LED will stay on permanently.
3) Press the key to be memorised on the transmitter, LED "RADIO" will start
blinking again.
4) To memorise another transmitter, repeat steps 2) and 3).
5) To exit the storage mode, wait until the LED is switched off completely.
limit device setting and opening command. An autoset operation
of the torque will be performed by keeping this button pressed
for 5 seconds (Fig.19).