NOTE: All user configu-
rable settings are stored
in non-volatile memory
and are retained while
power is off.
MODE SETUP
Mode setup menu allows user configure target
torque and angle minus and plus tolerances
and enable/disable Torque THEN Angle mode
and Torque AND angle mode.
1. From Configure menu, press ENTER button
while MODE SETUP selection is highlighted.
2. Mode Setup menu is displayed.
Menu Selections:
• EXIT: Exits Mode setup menu and returns to
Configure menu screen.
• TQ-% SETUP: Displays target torque minus
tolerance entry screen.
• TQ+% SETUP: Displays target torque plus tol-
erance entry screen.
• ANG-% SETUP: Displays target torque minus
tolerance entry screen.
• ANG+% SETUP: Displays target torque plus
tolerance entry screen.
• THEN DISABLED: Displays THEN Mode enable/
disable screen.
• AND DISABLED: Displays AND Mode enable/
disable screen.
3. Use UP/DOWN buttons to highlight menu
selections.
4. Press ENTER button while EXIT menu se-
lection is highlighted to return to Configure
menu.
SETTING TARGET TOLERANCES
This function will allow user to set plus and
minus tolerances for torque and angle targets.
1. From Mode Setup menu, use UP/DOWN but-
tons to highlight tolerance selection to setup
(TQ-%, TQ+%, ANG-% ANG+%) then press EN-
TER button.
E N G L I S H •
2. Tolerance screen is displayed.
3. Use UP/DOWN buttons to change tolerance
value. Range is 0 to 10% ( factory default for
minus tolerance is 0% and 4% for plus toler-
ance).
4. Press ENTER button to accept selection and
exit to Mode Setup menu.
NOTE: Green progress lights turn on at target
minus -% TOL.
NOTE: Red progress lights turn on above target
plus +% TOL.
NOTE: Plus tolerance is added to minimum
Preset value to define initial maximum value
when a Preset is first added.
ENABLE/DISABLE TORQUE THEN ANGLE
MODE
CThis function will allow user to enable or dis-
able Torque THEN Mode.
1. From Mode Setup menu, use UP/DOWN but-
tons to highlight THEN DISABLED (factory de-
fault) selection then press ENTER button.
2. TQ THEN ANGLE enable/disable screen is dis-
played.
3. Use UP/DOWN buttons to select ENABLE or
DISABLE selection.
4. Press ENTER button to accept selection and
exit to Mode Setup menu.
NOTE: Menu selection indicates current con-
figuration (ENABLED or DISABLED).
TORQUE 'THEN' ANGLE MODE
Torque THEN Angle mode is setup by first set-
ting a target torque and units then a target
angle before selecting Torque THEN Angle
mode. In Torque THEN Angle mode, when ap-
plied torque reaches target torque, wrench au-
tomatically switches to angle mode for angle
measurement. Progress lights indicate applied
torque progress while torque is measured and
angle when angle is measured. If torque is
below target torque when angle reaches tar-
get angle, green progress lights will not turn
on and if angle exceeds maximum angle, red
progress lights turn on indicating a potential
problem with fastener.
1. From target torque screen, use UP/DOWN
buttons to set target torque and UNITS button
to select torque measurement units then press
ENTER button.
U se r's m a n ua l