Urrea 6205 Manual De Usuario Y Garantía página 25

Torquimetro computorque
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

DOWN buttons then press ENTER button to dis-
play CLEAR ALL DATA screen. 3. In CLEAR ALL
DATA screen, highlight YES menu selection to
delete all stored data, or NO menu selection to
exit without deleting data.
4. Press ENTER button after making selection.
NOTE: If wrench is Locked (see Preset Lock in
Advanced section), Clear Data function is dis-
abled.
VIEWING AND CLEARING WRENCH CYCLE
COUNTER
Each time torque or angle target is reached,
wrench cycle counter is incremented. Maxi-
mum cycle count is 999999.
1. From target torque or angle screen, press
and hold ENTER button for 3 seconds.
2. Highlight CYCLE COUNT menu selection us-
ing UP/DOWN buttons.
3. Press ENTER button to display CYCLES screen.
4. To exit CYCLE COUNT screen without clear-
ing count, press ENTER button while EXIT
menu selection is highlighted.
5. To reset wrench cycle count to 0, highlight
CLEAR menu selection then press ENTER but-
ton.
6. EXIT menu selection is automatically high-
lighted after count is cleared. Press ENTER but-
ton to return to main menu.
NOTE: If wrench is Locked (see Preset Lock in
Advanced section) Clear count function is dis-
abled.
TARGET PRESETS (PSET)
PSET function gives user ability to configure 50
preset target torque or target angle settings,
each with a minimum (target), maximum (over
range) and batch count value. PSETs are stored
in non-volatile memory so that they are re-
tained while power is off.
ADDING A TORQUE PRESET
1. From target torque screen, select units of
measure.
2. Press and hold UNITS button for 3 seconds. 3.
ADD PRESET confirmation screen is displayed.
Highlight YES menu selection using UP/DOWN
buttons then press ENTER button. NO menu
selection returns to main menu without add-
ing a PSET.
4. MINIMUM TORQUE screen is displayed. MIN-
IMUM TORQUE is target value at which green
E N G L I S H •
progress lights, audible alert and vibrator turn
on. Initial MINIMUM TORQUE value is value
from target torque screen. MINIMUM TORQUE
can be set to any value within wrench torque
range by pressing UP/DOWN buttons. Once
desired target torque value has been set, press
ENTER button.
5. MAXMUM TORQUE screen is displayed
next. MAXIMUM TORQUE is torque value
above which red progress lights turn on. Initial
MAXIMUM TORQUE value will be MINIMUM
TORQUE plus 4%. Maximum torque value
can be set greater than MINIMUM TORQUE
value to 10% above wrench maximum range
by pressing UP/DOWN buttons. Once desired
value has been set, press ENTER button.
6. BATCH COUNT screen is displayed next. De-
fault value is zero. Batch count range is 0 to
99. Press UP/DOWN buttons to increment/dec-
rement batch count. Mode Count increments
each time target torque is reached if a batch
count of zero is entered. Mode Count decre-
ments if a non-zero batch count is entered and
resets to batch count value when count reach-
es zero. Once desired value has been set, press
ENTER button.
7. PSET target screen is displayed labeled with
next available PSET number from 01 to 50.
8. To enter additional torque presets, repeat-
edly press ENTER button until target torque
screen is displayed and repeat steps above.
NOTE: To select a stored PSET or manual target
torque or angle mode, repeatedly press ENTER
button until desired PSET or manual mode is
displayed.
U se r's m a n ua l