Hand-Held Pressure Indicator
CPH6200-S1 / CPH6200-S2
7. Calibration services
DKD-certificates - other certificates:
If the instrument requires calibration, we recommend returning it, along with its associ-
ated sensors, to the manufacturer. Only the manufacturer is able to verify the instrument's
basic settings and configuration, and if necessary correct them.
8. Specifications
Input
Pressure range in bar
Overpressure safety in bar 1
Burst pressure in bar
Resolution in mbar
Pressure range in bar
Overpressure safety in bar 35
Burst pressure in bar
Resolution in bar
Type of pressure
Accuracy of the measu-
ring chain
Calibration*
Display
Range of display
Units
CPH6200 Digital Instrument specific details:
Functions via key press
Functions via Menu
Data logger
Interface
(serial)
1)
Power supply
Power consumption
Working temperature
Air humidity
Storage temperature
Housing
Weight
EMV- / CE-conformity
1)
For the intrinsically safe version, the use of the interface is not permitted within an explosive atmosphere.
*)
Calibrated in vertical mounting position with lower pressure connection.
**) Not available for the intrinsically safe version CPH62I0.
{}
Items in curved brackets are optional extras at an additional price.
WIKA Operating Instructions Hand-Held Pressure Indicator
1: for CPH6200-S1;
0.1
0.16
0.25
0.4
1.5
2
2
2
2
2.4
2.4
0.1
10
16
25
40
80
50
80
42
96
250
400
0.01
gauge {absolute 0.25 up to 16 bar & vacuum on request}
0.2 % FS +/- 1 digit at reference temperature of 20 °C (optional 0.1 %)
factory calibration certificate (optional: DKD calibration certificate)
large LCD display for display of 2 values and additional information
max. -19999 up to 99999, depending on sensors used
can be selected from the following: mbar, bar, Pa, kPa, MPa, mmHg, inHg, psi
(dependent on range)
Min-, Max-memory, Hold, Tare, Offset-correction, Logger (Start/Stop)
Min-, Max-alarm (acoustic**/visual), Sea-level (barom. air pressure), Power-Off-
Function, measuring rate: 4/sec ("slow"); > 1000/sec ("fast"); > 1000/sec unfil-
tered ("peak-detect") [via "peak-detect" and min-/max-memory: pressure peaks
of 1.5 msec can be detected]
- discrete value-logger: up to 99 data points (incl. time-stamp) via key press
- cyclic-logger: automatic logging of up to 10000 values incl. time.
cycle-time: selectable between 1 ... 3600 seconds
RS-232 or USB interface via special interface cables
9V-zinc-carbon battery, alternative**: 9V rechargeable battery or mains supply
Cycle-time slow: < 1.6 mA, fast: < 7.0 mA, Low-Power-Logger-Fct.: < 0.3 mA
0 ... 50 °C
0 ... 95 % relative humidity without moisture condensation
-20 ... +70 °C
Impact-resistant ABS, membrane keyboard, transparent panels (CPH62I0 with
cover)
Approx. 160 g
The CPH6200 device corresponds to the essential protection requirements estab-
lished in the regulations of the council for the approximation of legislation of the
member countries regarding electromagnetic compatibility (89/336/EWG).
2: for CPH6200-S2
0.6
1.0
1.6
2.5
4
5
10
10
4.8
6
12
12
1
60
100
160
250
120
200
320
500
550
800
1000
1200
0.1
GB
4.0
6.0
17
35
20.5
42
400
600
1000
800
1200
1500
1700
2400
3000
1
23