Max. load to sterilise (including trays)
Equipment
Fabrics and porous material
Environmental conditions for the operation
Heat transmitted to air in working conditions
Maximum altitude
Max weight on support surface
Max weight by foot
Environmental conditions for storage
External connectors

1.3. WARRANTY

The QUAZ autoclave has a 24 month or 2,000 cycle WARRANTY, only if the instructions
described in this manual are followed carefully and periodic inspections are carried out.
(See Chapter 6: 'Maintenance'.)

1.4. UNPACKING

Upon receipt of the autoclave, check that the packaging and the equipment have no
damages. If any kind of damage is detected, inform the courier and the supplier.
The QUAZ autoclave and all the standard accessories and papers come in a reinforced box,
measuring :
• Quaz 17 l : 630 mm wide x 800 mm long x 630 mm high.
• Quaz 24 l : 630 mm wide x 1020 mm long x 630 mm high.
To unpack the equipment:
- Remove the top and side protection.
- Keep the two envelopes (papers and accessories) in a safe place
- Lift the equipment up, with the help of another person.

1.5. STANDARD ACCESSORIES

The autoclave comes with the following accessories:
1.-
5 perforated aluminium trays 280x180x20mm (Quaz 17 l),
425x180x20 mm (Quaz 24 l).
2.-
1 inox support for 5 trays/3 sterilisation vessels, size: 280x180x40 mm.
3.-
1 inox tray remover
4.-
1 tube with a union joint, to fill the tank with distilled water
5.-
1 tube with a union joint, to let out the waste water
6.-
Instruction Manual
7.-
1 instrument to open the door in case of emergency
8.-
1 SD memory card with 'QUAZ Viewer' software
9.-
Accompanying documents (see Annex 9.6)
Ambivalent support for 5 trays/3 sterilisation vessels
5 aluminium trays
280x180x20 mm
SD Memory card
Tray remover
Tube to fill/empty the distilled water
Tube to empty the waste water
Instrument to open the door in case of emergency
Sterilisation vessel 280x180x40 mm
(External) impact printer: 'QUAZ Printer'
(External) thermal transfer Printer for stickers
Water demineraliser: 'QUAZ Dem'
4.5 kg
1.5 kg
Temperature between 5ºC and 40ºC - Humidity between 40 and 90%
3000 kJ/h
2760 N/m²
172 N
Temperature between 0ºC and 50ºC - Humidity between 30 and 95%
RS 232 connector (connection external printer 'QUAZ Printer')
USB connector (PC connection SAT use)
SD Cards connector (cycle record)
Conductivity connector (water quality control 'QUAZ Dem')
Before moving the machine, always check that:
• The door is closed
• The water tanks are completely empty.
• It is disconnected from the power supply or from any other device (printer,
conductivimeter, etc.)
• It is disconnected from the automatic water supply and the water drain.
It should be moved by two people, putting their hands under the machine in the places
specified in the picture (at the sides) and pulling upwards.
After arriving at the final location for the machine, lift the front part up slightly and lean
the rear part on the wheels, and move hands away from this part. Then put the front part
down and move hands away.
• Especially make sure that:
• The support surface has the required dimensions described in section 3.1
• There are no elements in the way that may cause a fall when moving the
machine.
1
4
425x180x20 mm
6.0 kg
2.0 kg
3100 kJ/h
3000 m asl
2390 N/m²
206 N
3
5
6
9
2
7
8
7

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Quaz 24 l

Tabla de contenido