3.2 BOILER FIXING
To fit the burner to the boiler it is necessary to carry out the following:
➤
Widen, if necessary, the insulating gasket holes (3, fig. 3).
Fix the flange (5) to the boiler door (1) using four screws (4) and (if necessary) the nuts (2) interposing
➤
the insulating gasket (3) but keep unloosing one of the two upper screws (4) (see fig. 2).
➤
Put on the flange (5) the burner combustion head, tighten the flange with the screws (6) and lock the
loose screw (4).
N.B.: The burner can be fixed with the variable dimension (A) (see fig. 4). Anyway, make sure that the
combustion head crosses completely the boiler door thickness.
Fig. 2
3.3
PROBE-ELECTRODE POSITIONING
ATTENTION
➤
Ensure that the plate (3, fig. 5) is always inserted
in the flattening of the electrode.
➤
Lean the probe insulator (4) against the cup (2).
915T1
916T1
TYPE
17
A
3083
S7002
917T1
918T1
30
31
31
TYPE
A
915 T1
116 - 70
916 T1
114 - 100
917 T1
128 - 110
918 T1
167.5 - 145
3.5
±
0.3
3
6
GB
Fig. 3
D5012
A
Fig. 4
D5011
Fig. 5
2
A
±
0.3
1
4
D6088