5.3 Skylotec D-BOLT AP-058; AP-063-GE and AP-063-GPS anchor point
in installed condition on a steel structure.
Required fasteners:
The anchorage point D-BOLT is approved as a building product with NR, d [kN] = 12 kN as an attachment
device for 3 persons for fastening if the anchoring with fasteners (screws) is proved according to
technical building regulations.
In addition, the D-BOLT according to EN795 / A: 2012 and CEN / TS16415 (NR, d [kN] = 14 kN) is used as
a stop device for 3 persons.
The length must be selected depending on the material thickness of the substructure plus
the D-BOLT's maximum overall height.
Required tools:
§
Drill
Steel drill t=17 mm
§
§
Countersink
§
Possibly paint to correct installation site
§
Calibrated torque spanner with articulated head size 24
Safety information
For installation on steel or steel structure:
The torque should be 230 Nm with a 8.8 bolt M16 and 135 Nm with a stainless steel bolt A2-70. The spacing of holes
should be selected so that the anchor point always rests with its entire mounting surface on the steel.
The maximum bolt length should not exceed 8 x t (8 x 16 mm = 128 mm).
Thread machining is only approved with a material thickness of at least 16 mm.
The area where the anchor point is mounted on must safely absorb the static forces of 14 kN. The static load capacity
of this area must be demonstrated. Then secure the screw connection with liquid screw lock against unintentional
loosening.
All dimensions in mm.
MAT-MA-0005-00-GB
D-BOLT
20.07.2018
3
Number of users :
.
.
N
= N
Ɣ
= (6+2) kN
F,d
F,k
F
All directions
Page 9 of 19
Ɣ
F