Technical data
Low battery indication (PX 10R)
Protection class (except battery compartment)
Weight with battery (PX 10T)
Weight with battery (PX 10R)
Dimensions (PX 10T)
Dimensions (PX 10R)
Slope adapter range
Slope adapter maximum accuracy
5 Safety instructions
Read and understand all instructions. Failure to follow
all instructions listed below may result in serious
personal injury.
In addition to the information relevant to safety given
in each of the sections of these operating instructions,
the following points must be strictly observed at all
times.
5.1 Basic information concerning safety
a) Modification of the tool or tampering with its parts is
not permissible.
b) Observe the information printed in the operating in-
structions concerning operation, care and mainten-
ance.
c) Keep the measuring tool out of reach of children.
d) Have the tool repaired only at a Hilti service center.
e) Take the influences of the surrounding area into
account. Do not use the tool where there is a risk of
fire or explosion.
f)
Check that the tool functions correctly each time
before use.
g) Operation of the tool in the proximity of pregnant
women is not permissible.
h) Avoid bringing PUA 91 into contact with the skin or
eyes. If PUA 91 comes into contact with the eyes,
rinse the eyes thoroughly with water and consult a
doctor. If PUA 91 comes into contact with the skin,
wash the skin immediately with soap and plenty of
water.
5.2 Intended use
The PX 10 does not detect objects present in a wall and
therefore cannot guarantee that the user, when drilling,
will not contact electric cables, water or gas pipes or other
objects. Accordingly, the greatest care and attention
must always be exercised while working.
5.3 Proper organization of the workplace
Avoid unfavorable body positions when working on lad-
ders or scaffolding. Make sure you work from a safe
stance and stay in balance at all times.
Values
Battery status indicator in display shows blinking
frame: Remaining operating time: Min. 2 h
IP 56 protection against dust and water jets
0.24 kg (0.53 lb)
0.275 kg (0.61 lb)
160 mm x 95 mm x 33 mm (6.3" x 3.8" x 1.3")
210 mm x 95 mm x 33 mm (6.3" x 3.8" x 1.3")
90...45° (or 0° to 45°)
±2°
5.4 Electromagnetic compatibility
Although the tool complies with the strict requirements
of the applicable directives, Hilti cannot entirely rule out
the possibility of the tool being subject to interference
caused by powerful electromagnetic radiation, leading to
incorrect operation. Accuracy must be checked by taking
measurements by other means when working under such
conditions or if you are unsure. Likewise, Hilti cannot rule
out the possibility of interference with other devices (e.g.
aircraft navigation equipment).
5.5 General safety precautions
a) Check the condition of the tool before use. If the tool
is found to be damaged, have it repaired at a Hilti
service center.
b) The user must check the accuracy of the tool after it
has been dropped or subjected to other mechanical
stresses.
c) Check that the PX 10T transmitter is well secured
when attached to a working surface.
d) Although the tool is designed for the tough conditions
of jobsite use, as with other measuring instruments it
should be treated with care.
e) Although the tool is designed to prevent entry of
dampness, it should be wiped dry each time before
being put away in its transport container.
5.6 Electrical
a) Keep the batteries out of reach of children.
b) Do not allow the batteries to overheat and do not
expose them to fire. The batteries may explode or
release toxic substances.
c) Do not charge the batteries.
d) Do not solder the batteries into the tool.
e) Do not discharge the batteries by short circuiting as
this may cause them to overheat and swell up.
f)
Do not attempt to open the batteries and do not
subject them to excessive mechanical stress.
en