3.17 Nike Mini 28 kW Special series technical data.
ES
Nominal heat input
Minimum heat input
Nominal (useful) heat output
PL
Minimum (useful) heat output
Efficiency at nominal heat output
Efficiency at 30% nominal heat output
Casing losses with burner On/Off
TR
Chimney losses with burner On/Off
Gas nozzle diameter
RO
Supply pressure
Maximum working pressure of central heating circuit
Maximum working temperature of central heating circuit
IE
Central heating temperature range
Total volume of system expansion vessel
Expansion vessel factory-set pressure
Appliance water content
Available head at 1000 litres/hours flow rate
Hot water production useful heat output
Hot water hot water adjustable temperature
Hot water circuit flow limiter
Hot water circuit min. pressure (dynamic)
Hot water circuit max. working pressure
Min. draw of hot water
Specific flow rate (∆T 30°C)
Continuous service capacity (∆T 30°C)
Loaded boiler weight
Empty boiler weight
Power supply connection
Nominal power input
Installed electric power
Pump comsumption
Appliance electric insulation rating
Flue flow rate at nominal heat output
Flue flow rate at minimum heat output
CO
at Q. Nom./Min.
2
CO at 0% of O
at Q. Nom./Min.
2
NO
at 0% of O
at Q. Nom./Min.
X
2
Flue temperature at nominal heat output
Flue temperature at minimum heat output
Boiler fumes circuit resistance
NO
class
X
Weighted NO
X
Weighted CO
Type of appliance
Category
- * Temperature adjustment at domestic water flow of 7l/min. with inlet
temperature of 15°C.
- Flue temperature values refer to air inlet temperatures of 15°C.
- The data relative to hot water performance refer to a dynamic inlet pres-
sure of 2 bar and an inlet temperature of 15°C; the values are measured
86
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
%
%
G20
mm
1,30
mbar (mm H
O)
20 (204)
2
bar
°C
°C
l
bar
l
kPa (m H
O)
2
kW (kcal/h)
°C
l/min
bar
bar
l/min
l/min
l/min
kg
kg
V/Hz
A
W
W
-
G20
kg/h
73
kg/h
63
%
6,00 / 2,56
ppm
63 / 32
ppm
350 / 220
°C
100
°C
78
Pa
-
mg/kWh
mg/kWh
B11BS
II2H3+
directly at the boiler outlet considering that to obtain the declared data
mixing with cold water is necessary.
- The max. sound level emitted during boiler operation is < 55dBA. The
sound level value is referred to semianechoic chamber tests with boiler
operating at max. heat output, with extension of fume exhaust system
according to product standards.
30,9 (26571)
12,0 (10356)
27,9 (23994)
10,5 (9030)
90,3
89,3
3,6 / 1,07
6,1 / 0,24
G30
G31
0,78
0,78
29 (296)
37 (377)
3
90
38 - 85
4,5
1,0
2,9
25,9 (2,64)
27,9 (23994)
38 - 77
9,3
0,3
10
1,5
12,8
13,2
33,9
31
230/50
0,44
100
77,4
IPX4D
G30
G31
70
72
63
63
7,30 / 3,00
7,00 / 3,00
104 / 42
71 / 37
135 / 100
420 / 125
106
103
79
79
1,3
3
125
43
Tabla de contenido
loading

Tabla de contenido