List of parameters
ES
Minimum heating power
(DO NOT USE)
MAXIMUM heating power
PL
(DO NOT USE)
Heating switch-on timer
TR
Heating power output ramp
Heating switch-on delay on request from Envi-
ronmental Thermostat, Digital Remote Control
RO
or Remote Friend Control
Domestic water thermostat
IE
Circulating pump functioning
Functioning gas
Boiler mode (DO NOT USE)
(establishes if the boiler functions in
instanataneous or accumulation mode)
Once the parameter to be modified has been selected, confirm by turning
the main selector switch to Reset momentarily until the LED relative to
the parameter switches-off, then release.
Given the OK for selection, pass to the second level where it is possible to
set the value of the parameter selected. The value is indicated by the slow
flashing of one of the LEDs between 1 and 8. The value is selected by
rotating the heating temperature selector switch (11).
Once the value of the parameter to be modified has been selected, confirm
the selection by momentarily turning the main selector switch onto Reset
until the LED relative to the parameter switches off, then release.
Programming mode is exited if no operation is carried out for 30 seconds
or if the main selector switch is positioned at OFF from the "parameter
setting" level. For association of the LED to the relative value, see the
following tables:
Heating power. The boiler is produced and calibrated in the heating phase
at nominal power.
Permanent reduction of the timer The boiler has an electronic timing
device that prevents the burner from igniting too often in the heating phase.
The boiler has a standard supply of a timer adjusted at 180 seconds.
Heating switch-on timer (continuous variation)
30 seconds
55 seconds
80 seconds
105 seconds
130 seconds
155 seconds
180 seconds (Standard setting)
255 seconds
Heating ramp timing. The boiler distributes he maximum power set in
the previous parameter. The boiler performs an ignition ramp of about 650
seconds to arrive from minimum power to nominal heating power.
Heating ramp timer (continuous variation)
65 seconds
82
Flashing LED
130 seconds
(fast)
195 seconds
LED 1
390 seconds
LED 2
455 seconds
LED 3
520 seconds
LED 4
585 seconds
LED 5
650 seconds (Standard setting)
LED 6
Heating switch-on delay request from Room thermostat and Remote
LED 7
Friend Control. The boiler is set to switch-on immediately after a request.
In the case of particular plants (e.g. area plants with motorised thermostatic
LED 8
valves etc.) it could be necessary to delay switch-on.
Heating switch-on delay request from Room ther-
LED 8 and 1
mostat and Remote Friend Control (continuous
variation).
0 seconds (Standard setting)
54 seconds
131 seconds
180 seconds
206 seconds
355 seconds
400 seconds
510 seconds
Domestic water thermostat. With the setting of the "correllated"
thermostat, the boiler switches-off on the basis of the temperature set
using the sdomestic hot water adjustment selector switch (13). While
with the setting of the "fixed" domestic water thermostat, the switch-off
temperature is set on the maximum value sindependently from the position
LED
of the selector switch.
flashing
(slow)
LED 1
Domestic water thermostat
LED 2
Correllated
LED 3
Fixed (Standard setting)
LED 4
Circulating pump function. Two circulating pump operational modes can
be selected in heating phase.
LED 5
In "intermittent" mode it is activated from the environmental thermostat or
from the remote control, in "continuous" mode the circulation pump fun-
LED 6
ctions constantly when the main selector switch (12) is on heating mode.
LED 7
Circulating pump functione
LED 8
Intermittent (Standard setting)
Continuous
LED
flashing
(slow)
LED 1
LED 2
LED 3
LED 4
LED 5
LED 6
LED 7
LED 8
LED
flashing
(slow)
LED 1
LED 2
LED 3
LED 4
LED 5
LED 6
LED 7
LED 8
LED
flashing
(slow))
LED 1
LED 8
LED
flashing
(slow)
LED 1
LED 8