Yamaha EF2000iS Manual De Servicio página 124

Ocultar thumbs Ver también para EF2000iS:
Tabla de contenido
1
2
1
GENERATOR
4. Remove:
9 Generator rotor 1
TIP
9 Remove the generator rotor 1 using the
magneto rotor puller 2.
9 Fully tighten the tool holding bolts, making
sure the tool body is parallel with the gener-
ator rotor. If necessary, one screw may be
backed out slightly to level the tool body.
Rotor puller:
YU-33270, 90890-01362
5. Remove:
9 Generator fan 1
3-18
ENG
Tabla de contenido
loading

Tabla de contenido