Astralpool WELLMA Manual De Uso página 37

Cabinas de obra para baño de vapor
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Incorrect installation
The steam pipes have to be installed with a pitch towards the bath in case
the machinery were to be installed on the same floor as the bath, or towards
the generator, if the machinery were installed on a floor below.
The steam pipes have to be insulated with armaflex or similar material to
prevent the pipes from cooling and the steam from the water condensing in
the pipe.
No type of device that could plug the circulation of the steam or pressure or
flow regulators, valver or downgrades can be installed in the steam pipes.
A tip for the release of steam comes with the steam equipment. This is used
to keep the pipe in place and lead the steam jet to the floor.
See the following diagram.
Correct installation
8
One of the most important points of the installation is the location of the
steam tip. Keep in mind that the water leaves the tip at a temperature of 100
degrees, so it must be placed where the user will not get burnt.
A fan and a pvc pipe come with the equipment for the ventilation of the bath.
Whenever the installation so allows, place the air inlet above the steam tip so
that the steam will cool at the tip outlet.
Next, we will indicate the differenct correct possiblities for installing the tip.
SOLUCION D
SOLUTION D
Minimum 50m
Minimo 50 cm
SOLUTION B and C
SOLUCION B Y C
SOLUTION A
SOLUCION A