Fitting the pleated hose on the elbow –
SR 430 only
1
2
Push narrow hose clamp (1), marks
N
facing left, onto the elbow (2).
Push the pleated hose (3) onto the
N
elbow (2).
SR 430, SR 450
2
3
4
Push the hose clamp (1) onto the
N
pleated hose (3).
Line up the marks on the hose
N
clamp (1) and elbow (2) – as shown.
Secure the hose clamp (1) with the
N
screw (4).
1
3
4
2
1
Fitting the antistatic system – SR 450
only
3
Attach the antistatic wire (1) and
N
chain (2) to the blower housing with
screw (3).
Fitting the pleated hose on the elbow –
SR 450 only
1
2
Push the antistatic wire (1) into the
N
pleated hose (2).
English
1
2
15