The filter is not washable and cannot be regenerated. It must be replaced when led S1 flashes
or at least every 4 months. The alarm signal will only light up when the extractor motor is swi-
tched on.
Alarm signal activation
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or
at a later date. Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power
supply.
• Restore the connection by pressing and holding T1.
• Release the button. All five LEDs are turned on.
• Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:
-
LED flashes twice - Activated charcoal filter saturation alarm ENABLED.
-
LED flashes once - Activated charcoal filter saturation alarm DISABLED.
Replacing the activated charcoal filter
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the leds start to
flash.
Replacing the Filter
• Remove the metal grease filters
• Remove the saturated activated carbon filter by releasing the
fixing hooks
• Fit the new filter by hooking it into its seating
• Replace the metal grease filters.
20 W halogen light.
• Remove the snap-on lamp cover by levering it from under the
metal ring, supporting it with one hand.
• Remove the halogen lamp from the lamp holder by pulling
gently.
• Replace the lamp with a new one of the same type, making
sure that you insert the two pins properly into the housings on
the lamp holder.
• Replace the snap-on lamp cover.