Safety Instructions; Work Area; General Safety Warnings - Hilti SID 121-A Manual De Instrucciones

Ocultar thumbs Ver también para SID 121-A:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
the effects of vibration such as: maintain the tool and the accessories, keep the hands warm, organisation of
work patterns.
Noise information (measured in accordance with EN 60745):
Typical A weighted sound power level for the
SID 121 A and SIW 121 A
Typical A weighted sound power level for the
SID 144 A and SIW 144 A
Typical A weighted emission sound power level for
the SID 121 A and SIW 121 A
Typical A weighted emission sound power level for
the SID 144 A and SIW 144 A
Uncertainty for the given sound level
Additional information in accordance with EN 60745
Triaxial vibration values (vibration vector sum)
Impact driving of fasteners of maximum size for the
tool, SID 121 A and SIW 121 A, a
Impact driving of fasteners of maximum size for the
tool, SID 144 A and SIW 144 A, a
Uncertainty (K)
Battery
Rated voltage
Battery capacity
Weight
Temperature monitoring
during charging
Temperature monitoring
during discharging
Type of cell
No. of cells

5. Safety instructions

NOTE
The safety rules in section 5.1 contain all general
safety rules for power tools. The instructions at
5.1.2a, 5.1.2d, 5.1.2e and 5.1.3c are not relevant to
this power tool.

5.1 General safety warnings

WARNING! Read all instructions! Failure to follow all
instructions listed below may result in electric shock,
fire and/or serious injury. The term "power tool" in
all of the warnings listed below refers to your mains-
Printed: 07.07.2013 | Doc-Nr: PUB / 5070691 / 000 / 00
h
h
SFB 121 NiCd
12 V
2 Ah
0.72 kg
Yes
No
Nickel-cadmium SUB C
size
10
96 dB (A)
104 dB (A)
85 dB (A)
93 dB (A)
3 dB (A)
measured in accordance with EN 60745 2 2
7.4 m/s
12 m/s
1.5 m/s
SFB 126 NiMH
12 V
3 Ah
0.77 kg
Yes
No
Nickel-metal hydride
SUB C size
10
operated (corded) power tool or battery-operated
(cordless) power tool. SAVE THESE INSTRUCTIONS.

5.1.1 Work area

a) Keep work area clean and well lit. Cluttered or
dark areas invite accidents.
b) Do not operate power tools in explosive atmo-
spheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
B 144/2.6 Li-ion
14.4 V
2.6 Ah
0.55 kg
Yes
Yes
Lithium-ion
4
19
en
Tabla de contenido
loading

Este manual también es adecuado para:

Siw121-aSid 144-aSiw144-a

Tabla de contenido