Maintenance
Cleaning the inspection window
Clean the inspection window with water (no cleaning
agents). Use a soft sponge, woollen cloth or chamois
leather. Never use sharp objects or solvent to remove stains.
Fuses
Depending on the model, a fuse (2 A) is installed in the sup-
plied power cable. Only replace faulty fuses with ones of the
same type.
Trouble-shooting list
Fault
–
No flame or embers.
–
No noise.
–
The flame effect does not
respond to the switching
commands of the remote
control.
–
Function display of the
remote control does not
acknowledge the push of
a button.
–
Flame effect does not
function.
If this does not solve the problem, please contact the
Truma Service.
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
In other countries, the relevant regulations must be observed.
8
Cause / Action
–
Increase the brightness.
–
Increase the volume.
–
Point the remote control
toward the IR receiver
when sending switching
commands.
–
Check the function of the
batteries in the remote
control.
–
Check the power cable
and that the plug is insert-
ed firmly.
–
Check the fuse in the
onboard power supply /
power cable.
–
Check whether the supply
battery functions flawlessly
and if it is fully charged.
–
Reset the system.
To do this, interrupt the
power supply for at least
20 seconds.
Technical data
Power supply SELV (Safety Extra Low Voltage)
12 V DC
Current consumption
0.2 – 0.8 A
Quiescent current
< 1 mA
Weight
approx. 2.8 kg
The right to effect technical modifications is reserved!
Declaration of conformity
The device has been tested by the DVGW and is entitled to
bear the CE symbol. (Declaration of conformity – see operat-
ing instructions for the respective heater).
The previous CE product ident number of the heater
remains valid.