Service Menu - Abicor Binzel MFS-V2 Instructivo De Servicio

Ocultar thumbs Ver también para MFS-V2:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

MFS-V2
Trigger
Display
APD main menu:
ist
Select function
Heizung
Current temp=23°C
4
The heating function is only possible with the optional heating control module.
APD main menu:
plus
Select function
Heizung
Current temp=23°C
5
Setpoint= 27°C
minus
Heizung
6
The heating function is only possible with the optional heating control module.

14.4.5 Service Menu

The navigation in the Service Menu takes place by means of the arrow and numeric keys and the
confirmation by pressing the Enter key.
Trigger
Display
Service Menu:
=> Back
Service
3
Measuring wheel
Versions
Measuring wheel parameter:
Diam= 10.0
EncLin= 1024
The roll diameter at the wire is usually 10.0 mm. The number of lines of the encoder is usually 1,024.
Versions:
V3.1 30.06.05
Ht-V1.0-100304
Sa= 103 P=0
1234567890123456
00000000100000000000
00000001100
1234567890123456
0000000000000000
0000000000000000
Motor current
Axis1: 0.960A
Axis2: 1.030A
Description
Press this trigger to display the current temperature.
Press these keys to set the desired setpoint for heating.
Description
Press this key to go to the Service Menu.
The measuring wheel option is used to configure the optional wire actual
value encoder.
In the Versions option, all software versions can be displayed.
E-Box hand-held terminal
Hand-held terminal
E-Box Standalone Program
These inputs show the statuses of the hardware inputs.
The Outputs option allows the hardware outputs to be set (Up arrow) or reset
(Down arrow).
The motor current option allows the current motor currents (average value) of
both drives to be displayed.
Axis 1 = Slave drive
Axis 2 = Master drive
14 Options
EN - 25
Tabla de contenido