LEGRAND 430 523 Manual De Usuario página 25

Ocultar thumbs Ver también para 430 523:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

DIP SWITCH SETUP
Before in
stalling the camera, set up the DIP switch to configure the camera ID and the communication protocol.
Camera ID Setup
DID numbers of cameras are set up with binary numbers. See the examples shown below.
Pin
1
Binary
1
Value
ex: ID = 5
on
ex: ID = 10
off
The camera ID range is "1~255".
The factory default of the camera ID is "1".
Match the camera ID with the Cam ID setting of your DVR or Controller to control the camera.
If you are connecting a single camera to a controller, terminate the camera. When connecting more than one
camera to a single controller, terminate the last camera on the communication line. The last camera means
the camera farthest in cable length from the controller.
Note that the total length of the communication cable between a controller and the camera(s) on the same
communication line must be less than 1.2Km.
2
3
4
2
4
8
off
on
off
on
off
on
Camera ID must not be "0"!
25
5
6
7
16
32
64
off
off
off
off
off
off
8
128
off
off
Tabla de contenido
loading

Este manual también es adecuado para:

430 524430 525

Tabla de contenido