42 www.aeg.com
temperature. The yellow/green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
8.6 Building In
min.
55 mm
480 mm
10 mm
A)
supplied seal
B)
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
9. TECHNICAL INFORMATION
Hob dimensions
Width:
min.
min.
650 mm
600 mm
30 mm
560 mm
3 mm
11 mm
B
594 mm
8.7 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy ac-
cess in case a technical assistance inter-
vention is necessary.
A)
Removable panel
A
B)
Space for connections
Kitchen unit with oven
11 mm
The hob recess dimensions must obey
the indication and the kitchen unit must
be equipped with vents to let a continu-
ous supply of air. The electrical connec-
A
tion of the hob and the oven must be in-
stalled separately for safety reasons and
to let easy remove oven from the unit.
Length:
30 mm
min 20 mm
A
(max 150 mm)
60 mm
B
2
50 cm
2
360 cm
510 mm
2
120 cm
2
180 cm