Fig.27
BATT.1 12V 1,3Ah
BATT.2 12V 1,3Ah
Battery charger (OPTIONAL)
Battery Charger
Connector
Reversing Motor
To invert the motor polarity
reverse the position of
the 2 jumper leads.
1
2
= closing towards
right *
= closing towards
left *
* looking at the gate from inside
24 Vac
POWER SUPPLY
TRA
F1
F
N
230V 50Hz POWER GRID SUPPLY
1: YELLOW - Manual function button.
2: BLUE - Manual function button, also used for machine learning performances.
3: RED - Manual function and RESET button.
S1: Manual/Automatic selector switch.
Aprimatic Rx Connector: 3-pin connector used for Aprimatic plug-in Radio receiver connection.
Motor Connector: 5-pin connector - Includes Motor and Encoder.
Reversing motor: Motor polarity setting jumper
Battery Charger Connector: Plug-in connector for battery charger (OPTIONAL).
Batt.1-Batt.2: Back-up batteries 12V 1.3Ah (OPTIONAL).
TR 1: Trimmer for setting pause time before automatic closing (see par. 7.6).
TR 2: Trimmer for setting torque threshold (see par. 7.4).
TRA: Toroidal transformer 230V -24V.
F1: Safety fuse 3.15A (delayed).
Power LED: Lights up when the power is ON.
Blink-Light LED: Lights up in the same way as the flashing light and is used to check the remote control
unit self-learning.
11-pin and 2-pin terminal boards:
TERMINAL
FUNCTION
1 - 2
flashing light output
3
positive power TX and RX
4
negative power TX
negative power RX and common
5
for push-buttons and safety devices
6*
closing limit switch
7*
opening limit switch
STOP input
8
9
RX photocell input contact
10
pedestrian opening START
step-by-step START command
11
antenna inputs
12 - 13
* to reverse in case of closing toward left (see the reversing motor jumpers)
ELECTRONIC CONTROL UNIT DIAGRAM
Manual / automatic switch
Manual
Reversing Motor
POWER LED
Motor Connector
1
+
-
ENCODER
GND
+5Vdc
MOTOR
SIGNAL
FLASHING LIGHT
24Vdc 100mA Max
SETTING
24 VDC
+24 VDC
GND
GND
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Open
Normally Open
- 25 -
Automatic re-closing
Maximum torque threshold setting
TR1
1
2
3
YELLOW BLUE
RED
Automatic
S1
MEMORY MODULE
(optional removable version)
BLINK-LIGHT LED
2
3
4
5
6
7
8
9
10 11 12 13
Warning
panel without having fi rst read the instructions !!!
N.B.: Pay particular attention to the polarity with
which the battery is connected to the control unit.
Warning
using a 6A automatic differential switch with
threshold of operation 0.03A.
Warning
Any normally closed (NC) contact must be jumped
if not used.
Example:
5
6
Electrical connections
Radio module (OPTIONAL)
(STANDARD in the RACING KIT)
TR2
Aprimatic RX
CONNECTOR
Antenna braid
ANTENNA
START (Step by step mode)
START Pedestrian opening
Photocell contact
Stop
Opening limit switch
Closing limit switch
Do not install the control
Protect the power supply
7
8
9