Aprimatic ONDA 324 N Instrucciones Para La Instalación página 19

Idiomas disponibles
  • ES

Idiomas disponibles

4.2.3 Selecting the wheels
Wheel dimensions must be compatible with the guide
profi le, in good condition and capable of bearing the
weight of the gate; minimum diameter 120 mm.
If the wheels do not conform with the above they must
be REPLACED.
There should be NO MORE THAN TWO wheels and
they should be placed close to the extremities of the
gate.
4.2.4 Inspection of upper guides
There must be at least two upper guides arranged in line
with the wing, they must prevent the gate from swinging
while moving and not hinder the movement.
Some examples of installation are given below.
Fig.8
5.1
FIXING THE OPERATOR
There are two methods for fi xing the operator to the
ground:
• a foundation template with 4 anchor log bolts, sunk
in cement (the foundation kit).
• screws or chemical anchors can be used on ground
which is suffi ciently fi rm and fl at.
Warning
Other assembly methods where the motor base is
not horizontal are forbidden by the manufacturer.
Warning
When carrying out surveys the installer must check
that near the wing there is enough room to contain
the overall dimensions given in Par. 3.3.
- 19 -
Preliminary Operations
loading