Pre-Installation (continued)
LOCATION REQUIREMENTS
The exible exhaust hose allows placement of the air conditioner at least 20 in. from window or door.
Con rm you are using the correct size air conditioner for the space to be cooled, per sizing recommendations, below:
Area to be cooled
Up to 10 ft x 15 ft room
Up to 10 ft x 25 ft room
Up to 15 ft x 20 ft room
Up to 10 ft x 35 ft room
Up to 15 ft x 30 ft room
Up to 10 ft x 55 ft room
Up to 10 ft x 55 ft room
NOTE: Match BTUs to room use and location: Shaded room, reduce to next smaller size;
sunny room, increase to next larger size; for kitchens, increase to next larger size.
WARNING: The length of the exhaust hose is specially designed according to the
speci cation of the product. Do not replace, extend, or otherwise modify the hose.
Vertical Sliding Window
20 in.
(50 cm)
NOTE: For best performance, allow at least 20 in. of air space on all sides of the unit for good
air circulation.
□ Do not block the air outlet.
□ Provide easy access to the grounded 3-prong outlet.
□ To ensure proper function, DO NOT overextend or bend the hose. Make sure that there is
no obstacle around the air outlet of the exhaust hose in order for the exhaust system to
work properly. All the illustrations in this manual are for explanation purposes only. Your air
conditioner may be slightly different. The actual shape shall prevail.
DOE Capacity needed (BTUs)
150 sq. ft
5,000 Single Hose
250 sq.ft
6,000 Single Hose
300 sq. ft
7,000 Single Hose
350 sq. ft
8,000 Single Hose
450 sq. ft.
10,000 Single Hose
550 sq. ft
10,000 Dual Hose
550 sq. ft
12,000 Single Hose
20 in.
(50 cm)
Horizontal Sliding Window
20 in.
(50 cm)
9
20 in.
(50 cm)