Start-up
Pos: 61 /Pumpen/Schlammsauger/Air Flow LM/Inbetriebnahme Air Flo @ 7\mod_1202909789093_121.doc @ 44015
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Disconnect the power plug (Figure P, 44/46) prior to reaching into the water and
commencing work.
Attention! Danger emanating from the propeller rotating at high speed.
Possible consequences: Severe injury to limbs.
Protective measures: Only switch on the Air Flo with the protection grid fitted.
Switching on / Switching off (P)
The Air Flo switches on automatically when the power connection is established.
Switching on: Plug the shock-proof plug (44) of the 230 V unit in the shock-proof socket. Plug the CEE plug (46) of
the 400 V unit in the CEE socket.
Switching off: Pull the power plug (44) / CEE plug (46).
The control box (42) and the motor (overload) protection switch (43) are intended to protect the motor. The pump will
be switched off in the case of an overload.
Button (45): Press the button to restart the motor.
Red switch (47): Press the switch to trigger the motor (overload) protection switch. The motor will switch off.
Green switch (48): Press the switch to restart the motor.
Also read the section "Remedy of faults".
Pos: 62 /Alle Produkte/Überschriften/H1_Reinigung @ 7\mod_1202913260270_121.doc @ 44067
Cleaning
Pos: 63 /Pumpen/Schlammsauger/Air Flow LM/Reinigung Air Flo @ 7\mod_1202913074801_121.doc @ 44041
Disconnect the power plug (Figure P, 44/46) prior to starting cleaning work!
If necessary, clean the unit under clear water using a soft brush.
Pos: 64 /Alle Produkte/Überschriften/H1 Störungsbeseitigung @ 7\mod_1196625290699_121.doc @ 41521

Remedy of faults

Pos: 65 /Pumpen/Schlammsauger/Air Flow LM/Störungsbeseitigung Air Flo @ 7\mod_1202913366348_121.doc @ 44093
Attention! Danger emanating from the propeller rotating at high speed.
Possible consequences: Severe injury to limbs.
Protective measures: Disconnect the power plug (Figure P, 44/46) prior to starting work at the unit!
Malfunction
Pump does not start
Pump switches off after a short running period
Incorrect propeller rotational direction of the
400 V unit
Irregular water image effect, loud flow noise
Switch on the unit
Air Flo, 230 V: Allow the unit to cool down (approx. 30 seconds), then press the button (45) at the control box (42).
Pump will start.
Air Flo, 400 V: Press the green button (48) at the motor (overload) protection switch (46). Pump will start.
Pos: 66 /Alle Produkte/Überschriften/H1 Lagern / Überwintern @ 7\mod_1196625251745_121.doc @ 41495
Storage/Over-wintering
Pos: 67 /Pumpen/Schlammsauger/Air Flow LM/Lagern/Überwintern Air Flo @ 7\mod_1202913687520_121.doc @ 44119
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Pos: 68 /Alle Produkte/Länderkennzeichen/03===F=== @ 0\mod_1126476126844_0.doc @ 4432
Pos: 69 /Alle Produkte/Hinweise zur GAW @ 5\mod_1168260019787_200.doc @ 31664
Cause
No mains voltage
Pump overload
− Excessively soiled water
− Water temperature too high
− Filter basket soiled
− Propeller seized up due to soiling
− Motor defective
Mains phases in the CEE socket reversed
Filter basket soiled
Remedy
Check mains voltage
Clean, check supply lines
Clean filter basket
Only operate the unit at the water temperature
specified in the technical data
Clean the filter basket under running water
using a brush.
Remove soiling
Contact OASE
Ensure that the propeller rotates counter-
clockwise (CCW). Connect the mains phases in
the CEE socket to comply with the rotational
direction.
Clean filter basket
- GB -
15