Storage/overwintering
When the unit is in continuous operation it can remain in place at freezing temperatures.) Otherwise store the unit in-
doors in a dry room (room temperature).

Wear parts

• Membrane
• Aeration stone

Spare parts

The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.

Remedy of faults

Malfunction
The unit is not operating
The unit does not deliver any air or the amount
delivered is insufficient
The unit is unusually loud
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
www.oase-livingwater.com/spareparts
Cause
No mains voltage
The aeration stones are soiled
The air filter is soiled
Membrane is defective
Membrane is defective
Remedy
Check mains voltage
Clean the aeration stones
Clean the air filter
Replace the membranes
Replace the membranes