"tL": Temperature limit
The maximum temperature of the unit can be reduced to any value within the temper-
ature setting range with
and
"60". A setting to "--" deactivates the heating function.
Note: If the instantaneous water heater supplies a shower, the maximum temperature
was limited during the unit installation and the function is disabled.
"LL": Operation lock
Secure your settings with a four-digit PIN. Use
firm with
. The PIN entry follows. Use
entry with
.
Setting options:
"no" No restrictions (factory setting).
"SE" No parameters can be changed in the service menu without a PIN.
"In" The service menu can only be opened with PIN.
"tr" The temperature can only be changed with the memory keys without PIN.
"tL" As "In", additionally the setpoint can only be changed with PIN.
"SL": Shower limitation
If the appliance supplies water to a shower, the temperature must be limited to 55 °C.
Select the item "SL" and press and hold the button
down to zero.
Note: The function can only be deactivated by a specialist by restarting the unit.
"ri" WLAN
The WLAN can be activated as an access point here. The SSID and password can be
found on the type plate of the unit.
"FL" Flow limit
The behaviour of the motor valve can be set.
"no"
no flow limit (motor valve deactivated)
"Au"
automatic adjustment, i.e. flow limited so that the set desired temperature is
reached.
e.g. "9.0" limitation to a freely selectable value between 5 and 14 l/min
"tt" Thermal treatment
With this function, you can support thermal treatment of your unit and the down-
stream pipe network including fittings. This does not replace thermal disinfection
according to the recognised rules of technology.
• Select the item "
" and press and hold the button until the countdown has count-
t t
ed down to zero. The temperature is set to 70 °C.
• Tap hot water for at least three minutes to fully heat the pipes to the tap.
Reducing the set point or 30 seconds without water flow will end the treatment
cycle.
• The number and the accumulated duration and flow rate of all thermal treatments
are stored.
Notes:
Ensure that no one can be injured by the increased temperatures and that the
installation can withstand the stress.
The escaping water and the fitting become very hot! The water vapour should not be
inhaled.
"rE": Reset unit
All settings are reset to factory settings. Select the item "
button until the countdown has reached zero.
39
. The temperature limit is deactivated at the factory