Installing the SHLX
ELECTRICAL CONNECTIONS
WARNING: Field wiring connections and electrical grounding must comply with local codes,
or in the absence of local codes, with the latest edition of the National Electrical Code,
ANSI/NFPA 70, or in Canada, Canadian Electrical Code, CSA C22.1Part1.
ELECTRICAL CONNECTION POWER CORD:
• The electric power supply requirement for this
water heater is 120 VAC/60HZ, 2 Amps.
• The water heater comes with a three (3) pin
power supply cord. Use only a power outlet
with a ground terminal.
• Do not cut the power cord! (Extra charges
will apply if warranty claim is needed)
• The installation of an electric leakage
breaker is recommended. (GFCI)
• Keep any excess of the power supply cord
on the outside of the water heater.
• If local codes require hardwiring, see
instructions for "Hardwiring the Electrical
Connections".
WARNING: Shock hazard line voltage is
present. Before servicing the water heater,
turn off the electrical power to the water
heater at the main disconnect or circuit
breaker. Failure to do so could result in severe
personal injury or death.
Electric Wiring Diagram
PLEASE NOTE: SHLX IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO
Support: Support.Eccotemp.com
CHANGE WITHOUT NOTICE. PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR MORE INFORMATION.
Shop Online: www.Eccotemp.com
HARDWIRING THE ELECTRICAL
CONNECTIONS:
• Wiring should be carried out by a qualified
electrician in accordance with local codes.
• The water heater requires 120 VAC/60Hz
and should be properly grounded.
• DO NOT connect grounding wire to water
pipes, gas pipes, telephone cables,
lightning conductor circuits and to
grounding circuit of other equipment that
carry a ground-fault interrupter.
• An ON/OFF switch must be provided and
installed for the incoming 120VAC power.
• Wire the water heater exactly as shown
below. A wiring diagram is also found
inside of the cover panel.
• A green screw is provided in the junction
box for grounding connection.
• Connect the live wire to black leg wire and
the neutral wire to the white neutral wire.
CAUTION: Label all wires prior to
disconnection when servicing controls. Wiring
errors can cause improper and dangerous
operation. Verify correct operation after
servicing.