ECCOTEMP SHLX Serie Instrucciones De Instalación, Uso Y Mantenimiento página 26

Calentador de agua sin tanque para toda la casa
Idiomas disponibles

Idiomas disponibles

Installing the SHLX
VENTING CONT.
Only the 3" vent kit (purchase separately) for the SHLX or approved
Eccotemp Stainless Steel venting should be used for installation.
The wall thimble requires mechanical support from the wall sufficient to
support any incidental loads on the system. If the wall is not sufficient
enough to support the wall thimble, then appropriate additional framing
and/or blocking is required.
INSTALLATION PROCEDURE:
Prepare an opening for the wall thimble in the wall. The opening must
be 6.5" in diameter for a 3" vent system. The opening should be round.
The opening must be able to accommodate the 3" vent system and wall
thimble (purchased separately). Consult manual or building codes for
distance from flammable materials.
The wall thimble is designed to adapt to any wall thickness from 3.5" to
6" thick. If the wall is thicker than 6" the wall thimble may be extended
using a piece of 6" diameter snaplock or welded seam galvanized pipe
up to 6" long.
Select the larger diameter half of the wall thimble for the outside of the
wall.
• Apply a continuous bead of high quality silicone or silicone/latex
caulk on the inside of the outer flange. This will be the only weather
seal to keep moisture outside the building. Ensure a sufficient seal
is made.
• Position this portion of the wall thimble into the prepared hole from
the outside. Secure the assembly into the prepared opening using
fasteners as indicated by sheathing or structural members, sealing
the screw heads with more caulking.
• Use 4 hollow wall anchors, at least 1/8" in diameter and of appropriate
length for the thickness of the sheathing, if sheathing is particle
board or other composite material. Use 4 #10x1-1/4" wood screws
for plywood, solid wood sheathing or members. Use suitable masonry
anchors when passing through solid masonry walls. Reinstall the
decorative sheathing around the wall thimble. This assembly may be
painted to match the exterior decor.
• Slide the interior portion of the thimble into the inside hole. Be
certain the interior and exterior thimble halves overlap at least 1".
If insufficient overlap exists, extend the interior portion with single
wall galvanized pipe.
• Secure the vent section that protrudes through the wall thimble to
the 90° elbow attached to the water heater.
• The exhaust pipe should be sloped downward at an approximate 3°
grade in order to avoid rain (or condensation entering the heater)
through the exhaust pipe.
26
Support: Support.Eccotemp.com
PLEASE NOTE: SHLX IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO
CHANGE WITHOUT NOTICE. PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR MORE INFORMATION.
Shop Online: www.Eccotemp.com
1/4" per Foot
Downward Slope
Wall
Thimble
1/4" per Foot
Downward Slope
Wall
Vent
Thimble
Termination
Water
Heater
Water
Heater
Mounting Brackets
Side View
Inner Thimble
Outer Thimble
Mounting Brackets
Section
Section
Side View
Inner Thimble
Outer Thimble
Section
Section
Side View
Side View
Phone: 866-356-1992
Vent