Installing the SHLX
LOCATION
• Installation distances may vary by local code. It is the installer's responsibility to verify installation
requirements.
• Make sure before installation that the gas type you will use is the same type on the data plate.
• The water heater should be installed by professionals. Improper installation may cause failure or
dangerous conditions such as gas leaking or explosion.
• Failure to have the water heater installed by a professional will void your warranty.
• Water heater cannot be installed in an UN-VENTED bathroom, bedroom, basement, living room,
closet, outdoor, stairway or an exit area. If installed in an exit area, it must be at least 16.5 ft. or
more away from the exit.
• Vent pipe should extend from the wall at least 2". The terminal must be at least 1.64 ft away from
obstruction and must be well vented.
• Ensure a backflow preventer has been installed to the vent piping.
• Install a condensation trap and drain (as required).
• Vent pipe should slope 3° downward, to avoid condensing water and protect from rain entering.
• Vent pipe should avoid direct, strong wind because the downdraft will cause malfunction.
• The water heater should be installed far from any blockage, and with plenty of enough space for
installation and maintenance. Adequate clearances for servicing must be provided.
• The water heater should not be installed in the same room with a gas stove.
• When determining the floor clearance, a clearance of 12 inches must be maintained between the
vent pipe and combustible material. A side wall clearance of 10 inches and a top clearance of 16
inches must be maintained.
• The vent pipe can be up to 32ft in length with one elbow.
• The vent pipe should be installed with a flame retardant wall thimble. Owner must refer to vent
manufacturer's instructions and specifications. Eccotemp information can be found at www.
Eccotemp.com, please refer to page 24 for additional links. Installation guidelines for venting
provided by Eccotemp, who is solely responsible for venting installation accuracy.
• The power socket connecting the water heater should be grounded properly with a GFCI circuit
protector.
• The water heater should not be located in an area where leakage of the heat exchanger
or connections will result in damage to the area adjacent to it or to lower floors of the structure.
When such areas cannot be avoided it is recommended that a suitable catch pan, adequately
drained, must be installed under the water heater. The pan must not restrict combustion airflow.
• This water heater MUST NOT be installed in a laundry room or in the same room as the washer
dryer. Installation of the water heater in a laundry room or in the vicinity of a washer/dryer will void
the warranty.
• The water heater should be installed as close as practical to the vent termination to minimize vent
length and the number of elbows required for venting.