Preface
This manual is for the correct installation, use and maintenance of this product. Read it carefully
before using this product or carrying out maintenance. Replace the manual immediately if lost.
This product has been designed to meet the requirements of relevant EC directives. To maintain
this status, all installation, repair and maintenance work for this product is to be carried out by
qualified personnel using only original spare parts. Contact the nearest authorized distributor or
Nederman for advice on technical service and obtaining spare parts.
Nederman continuously improves its products' design and efficiency through modifications,
and reserves the right to do so without introducing these improvements to previously supplied
products. Nederman also reserve the right to, without previous notice, modify data and
equipment as well as operating and maintenance instructions.
2
Notices
This document contains important information that is presented either as a warning, caution or
note. See the following examples:
WARNING!
Warnings indicate a potential hazard to the health and safety of personnel, and how that hazard
may be avoided.
CAUTION! Type of risk.
Cautions indicate a potential hazard to the product but not to personnel, and how that hazard may
be avoided.
NOTE!
3
Description
3.1
Technical data
Table 3-1: Technical data
Weight, incl. hose
Maximum mounting height
Max working pressure
Ambient temperature
Material recycling
Dimensions
4
Installation
4.1
Mounting instruction
See Figure 2. The Hose Reel is delivered for ceiling mounting (item 1) but can also be used for
floor or wall mounting. Use wall bracket (item 2) for wall mounting. Only in exceptional cases
mount as items 3 or 4.
Item 5: The hose must not bend on the hose outlet. Select a level surface on which to mount the
reel. Ensure that suitable fixing bolts are used and that they are secure. The bolts must stand a
torque force of minimum 5600 N (Ser. 870), 7400 N (Ser. 876).
10
Type of injury.
Notes contain other information that is important for personnel.
Ser. 870
16 kg
4.0 m
2.0 MPa (290 psi)
−10 °C – +60 °C
71–74 weight-%
See Figure 1.
Ser. 876
26–30 kg
4.0 m
2.0 MPa (290 psi)
−10 °C – +60 °C
70–72 weight-%
See Figure 1.