EN
Hose Reel 876
5
Maintenance
Installation, repair and maintenance work is to be carried out by qualified personnel using only
original Nederman spare parts. Contact your nearest authorized distributor or Nederman for
advice on technical service.
NOTE!
maintained.
The following maintenance is recommended to be accomplished regularly or at least once a year.
•
Check the spring function by testing if the hose recoils properly.
WARNING!
• Check that swivel and hose couplings don't leak. Use leak detection spray. Change the seal if
required. Clean the swivel and couplings.
•
Check that the hose is intact. Clean the hose if oily or dirty.
•
Check the ratchet mechanism.
•
Check the fixing points of the reel on wall or ceiling.
5.1
Repair instructions
See Figure 7.
WARNING!
Before starting any operation in the reel:
• Turn off the supply of gas (air etc.).
• Neutralize the spring power by removing the hose stop and let the hose recoil.
Instructions for hose fitting, see Chapter '4.5 Hose fitting'. Instructions for changing the spring
cassette, swivel or seal comes with each spare part.
5.2
Spare parts
Contact your nearest authorized distributor or Nederman for advice on technical service or if you
require help with spare parts. See also www.nederman.com.
Ordering spare parts
When ordering spare parts always state the following:
•
Part number and control number (see the product identification plate).
•
Detail number and name of the spare part (see www.nederman.com).
•
Quantity of the parts required.
6
Recycling
The product has been designed for component materials to be recycled. Its different material
types must be handled according to relevant local regulations. Contact the distributor or
Nederman if uncertainties arise when scrapping the product at the end of its service life.
12
The service intervals in this chapter are based on the unit being professionally
Risk of fire.