GYS 075078 Manual De Instrucciones página 131

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
Display the current QuickLoad
At the bottom right of the screen, the QuickLoad number is displayed.
Stopping the QuickLoad in progress
To close the current QuickLoad, the user must return to the Job/QuickLoad menu and select «Close».
2- Open - QuickLoad management
The screen lists previously created QuickLoads.
Short presssing push-button no. 1 returns to the previous menu
Holding down push-button no. 1 ( ) deletes the selected QuickLoad or all the QuickLoads.
Holding down push-button no. 2 ( ) allows the selected QuickLoad to be modified.
Short pressing on push-button no. 2 (
Error codes
The following table shows a non-exhaustive list of messages and error codes that may appear.
Carry out these checks and inspections before calling in an authorised GYS technician.
If the user needs to open the product, they must turn off the power supply by disconnecting the electrical plug from the socket, and
wait two minutes for safety.
Codes
error
OVER-VOLTAGE FAULT
001
Check the electrical installation
UNDER-VOLTAGE FAULT
002
Check the electrical installation
005
Earth current fault
COOLING UNIT FAULT
006
Cooling unit not detected
FLOW ERROR
007
Cooling circuit blocked
WATER LEVEL ERROR
008
Check the coolant level
COOLING UNIT
009
Thermal protection
POWER SOURCE
010
Thermal protection
Fan
011
Fan default.
TRIGGER
012
A trigger is being pressed
MOTOR
015
Unable to reach the required speed
) allows you to see the details of each of the previously created QuickLoads.
Messages
Solutions
Have your mains supply checked by an authorised person.
Presence of a stray current. Check the cabling of the welding acces-
sories (torch, ground clamp, electrode holder, etc.)
The cooling unit is no longer being detected. Check the connection
between the cooling unit and the power source.
Check the continuity of the torch's coolant flow.
Check the fuse of the cooling unit.
Fill the tank of the cooling unit to the maximum (recommended coo-
lant: Ref. 062511)
Wait a few minutes for the cooling unit to cool down.
Ensure that the recommended duty cycle for the selected welding
current used is not exceeded.
Ensure that air inlets and outlets are not obstructed.
Wait a few minutes for the power source to cool down.
Ensure that the recommended duty cycle for the selected welding
current used is not exceeded.
Switch off the power supply by unplugging the mains connector, and
check that the fan is not blocked.
Remove the torch and check to see if the message is still active.
Check that the «Gas purge / Wire feed» switch is not blocked..
Check that the trigger on the MIG/MAG torch is not blocked or stuck.
Check the pressure settings on the wire-feeding rollers.
Check that the welding wire is not blocked in the torch liner.
19