MasterCool 52240-A Instrucciones De Operación página 4

Medidor digital con abrazadera
Idiomas disponibles
  • ES

Idiomas disponibles

Peak Detect Measurement
1. Set Function/Range Switch to desired A ~ or V ~ range.
2. Set the Clamp Meter into the "PEAK HOLD" mode by pushing the "PEAK HOLD" Switch. The LCD display will indicate
"P" when Peak Detect mode is measured.
3. Follow this procedure for AC voltage and Current measurement. The displayed reading is the maximum RMS value of a
surge in current or a Voltage pulse. The reading decays at the rate of about 1 digi/second.
GENERAL SPECIFICATIONS
• Display: 3-1/2 digit LCD (1999 count) with P (Peak Hold), H (Data Hold), "–" "BT" (Low Battery), "~" "V" "A" "Ω" "KΩ"
"KHz" and decimal annunciators
• Sampling rate: 2.5 time per second
• Diameter of conductor: 40 mm max
• Polarity: automatic "–" negative polarity indication
• Range selection: all ranges are measured by single range switch operation
• Over range indication: highest digit of (1) or (-1) is displayed
• Low battery indication: "BT" appears on display in the last 20% of battery life
• Battery life: up to 200 hours with Alkaline battery
• Power requirements: single 9V battery
• Operating temperature and humidity: 0˚ to 40˚C (32˚ to 104˚F) below 80% RH
• Storage temperature and humidity: -10˚ to 60˚C (14˚ to 140˚F) below 80% RH
• Dimension: 8.2" (l) x 2.6" (w) x 1.3" (h)
(208 x 65 x 31mm)
• Weight: 10.9 oz (308 g) including battery
ELECTRICAL SPECIFICATIONS
• Accuracies are ± (% reading + number of digits) at 23˚C ± 5˚C below 80% RH
1. General Measurement
AC Current
Range
20A
200A
600A
DC Voltage
Range
600V
AC Voltage
Range
200V
600V
Resistance (
)
Range
200Ω
20KΩ
Frequency (Hz) (10Hz ~ 2KHz)
Range
2KHz
Continuity Check (
)
Range
4
Resolution
Accuracy (50Hz/60-Hz)
10mA
100mA
1A
Resolution
1V
± (0.8% rdg + 2 dgts)
Resolution
Accuracy (40Hz~400Hz)
100mV
± (1.2% rdg + 3 dgts)
1V
Resolution
Accuracy
100mΩ
± (1% rdg + 2
10Ω
Resolution
Accuracy
1Hz
± (1% rdg + 2
Description
Built-in buzzer sounds if conductance
is less than 100
± (2% rdg +5 dgts)
Accuracy
Input Impedance
Max. Open Circuit Voltage
dgts)
Max. Input Sensitivity Max. Allowable Applied Voltage
100mVrms
dgts)
Max. Open Circuit Voltage
www.mastercool.com
Overload
Protection 1000A (within 30 sec.)
Overload Protection
10MΩ
Input Impedance
10MΩ
3.5V
0.3V
3.5V
600V
Overload Protection
600V
Overload Protection
600V
600V
Overload Protection
600V
loading