GE JVM1950 Intrucciones De Instalación página 17

Ocultar thumbs Ver también para JVM1950:
Idiomas disponibles

Idiomas disponibles

Installation
Instructions
I_
Roll the blower unit 90° so that fan blade openings
are facing out the back of the oven.
Before Rolling
After Rolling
Back of
Oven
3ack of
Oven
[_
Locate the two "knockout" plates, on the rear oven
panel, near the top of the oven.
Using tin snips, carefully cut the web area from the
two holes side-by-side (that secure the knockouts to
the oven). Cut all four webs on both rear knockouts;
this will allow the ventilation fan airflow to exhaust
out the rear of the oven.
A,-,^,
,I-|_,
Jll_._/_U/I
_/I_1 : Be sure to trim the sharp
edges from the openings after removing the
knockout plates.
OvenReorPanel
[_
Place the blower unit back into the opening.
Snip all 4 webs
on each knockout
panel and
remove the metal
knockouts for rear
airflow.
!
WA RN IN G: Risk of electric shock
can cause injury or death. Do not pull or stretch
the blower unit wiring, make sure the wires are
not pinched..
NOTE:The blower unit exhaust openings should
match exhaust openings on rear of microwave.
I_
Attach the exhaust adaptor to the rear of the oven
by sliding it into the guides at the top center of the
back of the oven.
Exhaust Ad%tor
Damper
(hinge side up)
Slide
exhaust
adaptor into
guides on
oven rear
Back of
Oven
Guides
Push down securely until it is in the lower locking
tabs. Take care to assure the damper hinge
is installed so that it is at the top and that the
damper swings freely.
[_
Close the blower plate so it is closed over the top
tab of the exhaust adapter. Secure with the screw
removed earlier.
BlowerPlate
\
Back of
Oven
Screw
Exhaust Adaptor
17