ELICA VIRTUS MULTI 60 TFT Manual De Usuario Uso Y Mantenimiento página 18

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
INSTALLATION - Electrical connection
The instructions below are intended for the skilled technician who will install
the cooker, regulate it and perform technical maintenance and who will ensure that
these operations are carried out in the most correct way possible, in compliance
with the regulations in force. Important: the cooker must be disconnected from the
electric socket before performing all regulating or maintenance operations.
Installation rules
This appliance complies with the following directives
DIRECTIVE 2002/96/CE
LOW TENSION DIRECTIVE 2014/35/EU
ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 2014/30/EU
REGULATION No. 1935/2004 (contact with foods)
The installation must be done in a workmanlike manner and in full compliance
with the regulations in force concerning electrical installation. Otherwise the ma-
nufacturer declines all responsibility. In this booklet you will also find the wiring
diagram of your appliance.
The appliances are designed to be connected to the voltage shown on the data
plate.
Before connecting the appliance to the mains, make sure that:
• The characteristics of the electromagnetic switch or of the socket can withstand
the load of the equipment (see data on the plate);
• The power supply system must have an effective earth connection.
The appliance is supplied with a cable without plug: the connection must be made
taking into account that the yellow-green cable is the earth conductor and must
never be interrupted.
The socket must be visible and reachable so that you can easily disconnect the
appliance.
For direct connection to the network, it is necessary that:
• The limiting valve and the domestic system can bear the load of the equipment
(see serial number plate);
• The power supply system is equipped with an effective ground connection;
• The socket or omnipolar switch, with a minimum opening of 3 mm, is easily
accessible once the appliance has been installed;
• A landline disconnect switch is incorporated in accordance with the installation
rules.
never be interrupted even by the switch. The
power supply cable must be positioned so
that it does not come into contact with surfa-
ces that have a temperature higher than 50 °
C above the environment. If it is necessary to
replace the power supply cable, contact the
assistance service.
INSTALLATION - Wiring diagrams
KW
MODEL
(230V)
60
3,2
91
3,4
Key
00
Black
Brown
11
22
Red
33
White
Yellow
44
Yellow-Green
45
55
Grey
66
Blue
The yellow-green earth conductor must
Absorption (kW)
M
Terminal block
MG
Roaster
Door microswitch
MP
N
Neutral
NTC Temperature probe
P
Timer/Programmer
P
Timer/Clock
R1
Upper resistance
C
Commutator
CP
Cooking probe
DU
Wax thermal actuator
EF
discharging steam
Functions encoder Thermostat
ET
encoder
F
Thermostat encoder
FLC Filter
K1
Earth wire terminal block
K2
" " Lower resistance
K3
" " oven fan
K4
" " circulating resistance
K5
" " upper resistance
K6
" " oven light 1
K7
" " oven light 2
K8
" " roaster
K9
" " cooling fan
K11
" " oven thermostat
K12
" " programmer/timer
K15
" " frame
L1
Oven light
L2
Oven light
Wiring diagrams
18
Lower resistance
R2
R3
Grill resistance
R4
Circulating resistance
Oven warning light
S1
Mains warning light
S2
SD
Display board
SE
Selector
Power board
SP
SS
Probe board
T
Grill thermostat
TF
Oven thermostat
TS
Safety thermostat
TT
Bypass thermostat
TST Safety cooling fan thermostat
V
Oven fan
VT
Cooler fan
SA
Power supply board
GL
LED ring
PT Temperature probe PT1000
loading

Este manual también es adecuado para:

Virtus multi 90 tft