POWER CONNECTIONS
Before
electrical supply.
The unit should only be opened by authorized and qualified /
competent electricians.
Please refer to illustrations below for the connection terminals
sequence:
VIARIS UNI
VIARIS UNI+
VIARIS UNI+ BT2
On the VIARIS UNI+ and VIARIS UNI+ BT2 chargers that optionally carry the
Schuko plug socket (N/A in UK), the maximum power of the connection
should be 32 A + 14 A for single-phase, and 3x32 A + 14 A for three-phase.
In some cases, in which your charger has the extra MID meter or electrical
protections, connection terminals cannot be included by space, so the
connections will be made in the own counter or protections that will be
signalled in the correct order of the phases.
accessing
the
1PH+N
230 V~ 32 A
terminal
connectors
3x230/400 V~ 3x32 A
60
isolate
the
3PH+N
loading