User Guide can be downloaded from: heating.danfoss.com.
1 . Installation must be done by an authorised
electrician .
2. The room thermostat should be installed at approx.
1.5 m above floor and where the effects of sunlight,
draught or other heat sources (eg. TV's) are avoided,
see fig. 1 on page 44.
3. First loosen lower retaining screw and carefully
remove back plate, see fig. 2 on page 44.
4. Mount back plate direct to wall or on wall box and
wire according to application, see fig. 3 & 6 (pages
44 and 45).
5. Remove battery backup tab, see fig. 4 on page 45.
6. Locate hooks at top of front part into top of back
plate and lower into position and tighten retaining
screw.
2 . Dimensions and Wiring
See fig. 5 for dimensions and fig. 6 for wiring diagram
on page 45.