Pedestrian Open/Close Programming; Selection Of Modes And Control Panel Functions (Sw) - Erreka PUMA Manual Del Instalador

Accionador para puertas corredera
Ocultar thumbs Ver también para PUMA:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

5

PEDESTRIAN OPEN/CLOSE PROGRAMMING

Start programming mode
Programme the slowdown start points
Finish the programming mode
The pedestrian opening and closing of the gate
will be memorised.
The positions in which the gate begins to slow
down, both on opening and in closing, will also
be memorised.
6

SELECTION OF MODES AND CONTROL PANEL FUNCTIONS (SW)

Using SW2, choose the required options (see "SW2 functions" on page 42).
PROGRAMMING AND STARTUP
1 Ensure that DIP9 is configured correctly (see "Limit
switches configuration (DIP9)" on page 41).
2 Close the gate by pressing PUL1.
3 Place DIP7 in "ON" to enable the encoder.
If the encoder is not enabled (DIP7=OFF),
operation times will be memorised.
4 Place DIP8 in "ON" (slowdown).
5 Place DIP1 and DIP3 in "ON"; DIP2, DIP4, DIP5 and
DIP6 in "OFF".
DL3
lights
up,
programming mode.
1 Start to open the gate: press ST2; the gate begins
to open.
2 Start slowdown in opening: press ST2 (or A.P. or
the transmitter) at the point chosen for the start of
slowdown (DA1).
3 Finish the pedestrian opening: press ST2 at the
required position for the end of pedestrian opening.
4 Start closing the gate: press ST2; the gate begins
to close.
5 Start slowdown in closing: press ST2 (or A.P. or
the transmitter) at the point chosen for the start of
slowdown (DC1).
6 Wait for the gate to come to a halt due to the
action of the closing limit switch.
1 Place DIP1 and DIP3 in "OFF".
DL3 will remain off.
indicating
that
it
is
PUMA operator for sliding gates
in
45
Tabla de contenido
loading

Este manual también es adecuado para:

Puma pus400ecPuma pus400ecm