Functioning Modes; Obstacle Detection Functioning - Erreka PUMA Manual Del Instalador

Accionador para puertas corredera
Ocultar thumbs Ver también para PUMA:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

3

FUNCTIONING MODES

Automatic mode (DIP4=ON)
Opening: this begins by activating the key command
(transmitter, magnetic key, key switch, etc).
• Step-by-step opening (DIP3=ON): if the key
command is activated during opening, the gate
comes to a halt. The gate closes if operated again.
• Collective opening (DIP3=OFF): during opening,
the control panel does not obey the key commands.
Step-by-step mode (DIP4=OFF)
Opening: this begins by activating the key command
(transmitter, magnetic key, key switch, etc).
• Step-by-step opening (DIP3=ON): if the key
command is activated during opening, the gate
comes to a halt. The gate closes if operated again.
• Collective opening (DIP3=OFF): during opening,
the control panel does not obey the key commands.
4

OBSTACLE DETECTION FUNCTIONING

The gate can detect an obstacle in two ways:
A- Detection by photocell or strip
Closing safety device (SG.C)
During opening: the closing safety device (SG.C.) does
not run.
B- Direct detection (built-in safety) (DIP7=ON)
During opening
If, during opening, the gate collides with an obstacle,
the gate inverts the operation direction and gently
closes, remaining on standby until a new key command
is received.
DESCRIPTION OF THE PRODUCT
S t a n d b y : t h e g a t e r e m a i n s o p e n d u r i n g t h e
programmed time.
• Automatic mode optional (only if DIP5=ON): if,
during standby, the key command is activated, the
gate begins to close.
• Non-automatic mode optional (DIP5=OFF): if,
during standby, the key command or the photocell
is enabled, standby time starts again.
Closing: the closing operation starts once stand-by
time is finished.
If, during closing, the key command is activated, the
gate stops and then inverts operation direction and
opens completely.
Standby: the gate remains open until a key command
is received.
Close: the closing process begins by running the key
command (transmitter, magnetic key, key switch, etc).
If, during closing, the key command is activated, the
gate stops and then inverts operation direction and
opens completely.
During closing: if, during closing, the closing safety
device (SG.C) is enabled, the gate inverts operation
direction and opens completely.
During closing
If, during closing, the gate collides with an obstacle, it
inverts operation direction and opens completely.
PUMA operator for sliding gates
33
Tabla de contenido
loading

Este manual también es adecuado para:

Puma pus400ecPuma pus400ecm

Tabla de contenido