DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
1
Gate
2
Rack
3
Operator with control panel
4
Magnetic key or proximity key reader
5
Wall pushbutton/key switch
6
Antenna
7
Closing safety photocells
8
Limit switch magnets
9
Mechanical strip
10 Traffic light
ELECTRICAL CABLING:
Element
A: Main power supply
B: Flashing light
C: Photocells (Tx / Rx)
D: Pushbutton/wall key
E: Antenna
Fig. 1
Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
11 Flashing light
12 Gate stopper (with spring)
Nº threads x section
2
3x1.5mm
2
2x0.5mm
2
2
2x0.5mm
/ 4x0.5mm
2
2x0.5mm
k
Coaxial cable 50
(RG-58/U)
For greater safety, Erreka recommends installing
photocells (7) and safety strips (9).
Maximum length
30m
20m
30m
50m
5m
PUMA operator for sliding gates
English