Consider the pictures on the fold-out page.

Changing the battery pack

2
Inserting battery pack
click
Removing battery pack
2
Consider the pictures on the fold-out page.
CAUTION
Risk of injury
Always switch off the power tool before adjusting

settings!

Changing direction of rotation
• Switch to the left = clockwise rotation
8

Commissioning

BP/C 18
1
Settings
• Switch to the right = counterclockwise rotation
You can change gear using the gear switch [1-7].
Fastening
Select the correct torque setting:
[1-9]
Position 1 = low torque
Position 12 = high torque
Battery pack is ready for use immediately upon
delivery and can be charged at any time.

Light and battery capacity indicator

The LED on the lamp [1-2] is both a light and
a battery capacity indicator .
Press the LED light switch [1-1]:
1x ... LED, working area illumination
2x ... capacity indicator, indicates the charging
state of the battery pack (not with NiCd and
NiMH battery packs)
LED green – lit continuously:
charged > 60 %
LED green – flashing slowly:
charged 30 % – 60 %
LED green – flashing quickly:
charged 0 % – 30 %
LED yellow – lit continuously:
battery is empty
LED red – lit continuously: bat-
tery temperature is outside the
permitted range.
LED red – flashing: indicates a
general fault, e.g. incomplete
contact, short circuit, battery
pack faulty, etc.

Changing gear