JBM 50942 Manual De Instrucciones página 7

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
3. ELECTRICAL SYMBOLS
DC (Direct Current)
AC (Alternating Current)
DC or AC
Important safety information. Refer to
the manual
Dangerous voltage may be present
4. PANEL DESCRIPTION
5. SPECIFICATIONS
Accuracy is guarantied for 1 year 23°C±5°C less than 80%RH
5.1. DC VOLTAGE
RANGE
RESOLUTION
200mV
0.1mV
2V
1mV
20V
10mV
200V
100mV
1000V
1V
Input Impedance: 10MΩ
Overload Protection: 1000V DC or 750V AC rms
Max. Input voltage: 1000V DC
5.3. TEMPERATURE
RANGE
RESOLUTION
-40 ~
1°C
1370°C
Earth ground
Low battery
Fuse.
Diode
ACCURACY
±(0.5% of rdg + 3 dgts)
±(0.8% of rdg + 5 dgts)
±(1.0% of rdg + 5 dgts)
ACCURACY
-40°C~150°C:±(1.0% + 4)
150°C~1370°C:±(1.5% + 15)
Continuity test
°C
Centigrade
Conforms to European Union directive
Double insulated
Function Table
Model
LOGIC
5.2. AC VOLTAGE
RANGE
RESOLUTION
200mV
0.1mV
2V
1mV
20V
10mV
200V
100mV
750V
1V
Input Impedance: 10MΩ
Frequency Range: 40Hz ~ 400Hz
Overload Protection: 1000V DC or 750V AC rms
Response: Average, calibrated in rms of sine wave
Max. Input voltage: 750V AC rms
With K-type Thermocouple
· 7 ·
DT9208
DC
AC
DA
AC
?
hFE
CA
ºC
Hz
ACCURACY
±(1.2% of rdg + 5 dgts)
±(1.0% of rdg + 5 dgts)
±(1.2% of rdg + 5 dgts)
loading