Upper line: Parameter
dd.mm.yyyy
hh:mm
Keylock
WLAN reset
6.2.2 Information retrieval
Upper line: Type of informations
Fault protocol
(=alarms log)
up time
(=operating time)
total pump hours
(=total pumping time)
pump starts
(=number of starts)
next maintenance
6.2.3 Warnings and alarm messages
When an alarm occurs, a message specifying the type of alarm is displayed on the screen.
The corresponding data is recorded in the alarm log, with the name specified in the "Designation in the alarms log" column.
Lower line
Fault load
The control box has detected a current consumption lower than 0.5 A: either the pump is
not connected or a phase is missing.
NOTE: This error can be suppressed by setting the motor current monitoring value to 0.0
A in the "max. current" menu.
Fault Pump 1
The motor consumption has reached the value set in the "max. current": therefore, the
control box has stopped the pump.
Fault high water
The sensor signals a high water level alarm and switches the pump on. The HW alarm is
automatically reset when the ON level is reached again.
Fault I<3mA
The external sensor is selected but the current remains below 3 mA. The cable may be
disconnected or the sensor may be defective. The fault is automatically reset when the
sensor current is within the normal range.
Fault SW
The float switches (SW) turn on in the wrong order.
Pump
Activation of the thermal control of the pump motor.
The TH1 error is automatically cleared after the motor has cooled down; TH2 must be
Fault TH1
cleared manually.
Fault TH2
Phase error
Phase inversion in the connection to the control box of a three-phase pump.
To correct the problem, switch two phases.
Fault ATEX
The ATEX mode is activated and the water level is below the OFF level of the pump.
Run-time alarm
The pump runtime monitoring (menu "run-time") has been exceeded three times in
succession.
7. WARRANTY CONDITIONS
The device is guaranteed for two years from the date of purchase subject to installation, use and maintenance in accordance with
this manual.
The invoice in your possession serves as proof of warranty. During this warranty period, we will, at our discretion, either
repair or replace all defects due to material or manufacturing faults in the pump free of charge.
Wear and tear is excluded from the warranty. We do not accept any liability for consequential damage due to equipment failure.
Lower line: Parameter value
Help to choose
Value according to the setting
on
off
Lower line: Value
(Informations on the value)
DD.MM YYYY default
hours: XX
(in hours)
P1 XXXX
(in hours)
P1 XXXX
(in number)
within days: XXX
(in days)
Meaning
Setting the date and time
Enables/disables the automatic key lock.
See 6.1.1 Keys > Managing the automatic key lock
disabled
To scroll through the log, press
between the alarms with
chronological order.
It is not possible to change the data.
Indicates the cumulative operating time of the control box in hours.
The value can be reset to 0 with
Indicates the cumulative running time of the pump in hours
The value can be reset to 0 with
Indicates the number of starts of the pump.
The value can be reset to 0 with
Indicates the number of days until the next maintenance. The
information is saved every 4 hours. The initial value can be preset
between 365 and 0 days.
24
Meaning
Meaning
then switch
. The last 32 alarms are saved in
.
.
.
Buzzer
Designation in
the alarms log
Yes
Load
Yes
IP1
Yes
HW
Yes
I<3mA
Yes
SW
Yes
Pump
TH1
TH2
Yes
Dreh
Yes
Atex
Yes
Time