Alemite 339359-A1 Manual De Instrucciones página 12

Idiomas disponibles

Idiomas disponibles

CAUTION *

Do not operate this pump
without personal protective
equipment. Pump can
generate noise levels above
85 dB that could result in hearing loss.
Failure to comply could result in
personal injury.
WARNING

Do not exceed lowest pressure rating of
any component in system.
Failure to comply may result in
serious injury or death.

WARNING
Do not operate pump with broken,
missing or defective parts. Replace
defective parts prior to operation.
Failure to comply may result in
serious injury or death.
WARNING

Do not operate with leakage in system.
Disconnect air to motor.
Failure to comply may results in
serious injury.
Air line components
Item
Description
338860
Moisture separator/regulator and gauge combination
5604-3
Moisture separator
7604-B
Regulator and gauge
5904-3
Lubricator
1)
Although air motor is lubricated at factory, the life of motor can be extended with use of a lubricator.
Bench test
NOTE
Perform the following procedures at a
pressure not to exceed 20 psi (1.4 bar).
With air pressure at zero:
1 Connect air to inlet of air motor.
2 Slowly supply air pressure to pump motor.
3 Pump should cycle. If pump does not cycle,
refer to Troubleshooting, page 13 for
details.
Priming
With air pressure at zero:
4 Connect product hose to material outlet.
5 Direct hose into an appropriate collection
container.
6 Place pump in product.
7 Slowly supply air pressure to pump motor.
8 Allow pump to cycle slowly until system and
product is free of air.
9 If pump does not prime, refer to
Troubleshooting, page 13 for details.
1)
Stall test
With air pressure at zero:
10 Attach a control valve to outlet hose of
11 Set air pressure to 35 psi (2.4 bar).
12 Operate control valve into a container.
13 Allow pump to cycle until system and
14 Shut off control valve.
15 Set air pressure to 100 psi (7 bar).
16 Visually inspect pump for external leaks.
17 Pump should not cycle. If pump does not
Leakage
18 Check motor for air leakage.
19 If motor leaks, refer to 670628 for details.
Installation
Additional items that should be incorporated
into air piping system are illustrated in
Air line components, .
Table 5
* Indicates change.
12
pump.
product is once again free of air.
stall, refer to Troubleshooting, page 13
for details.
loading

Este manual también es adecuado para:

339359-b1339359-c1