• Wait until the electrical tool has come to a stand-
still before setting it down. The tool attachment can
get caught and this can lead to loss of control over the
electric tool.
• Hold the device by the insulated gripping surfaces
when carrying out work where the screw or the
tool attachment may hit hidden power lines. Con-
tact between the screw or tool attachment and a live
power line can also electrify metal device parts and
lead to an electric shock.
Residual risks
The product has been built according to state-of-the-
art and the recognised technical safety rules. Howev-
er, individual residual risks can arise during opera-
tion.
• Damage to hearing if the stipulated hearing protection
is not worn.
• Residual risks can be minimised if the "Safety Instruc-
tions" and the "Intended Use" together with the oper-
ating manual as a whole are observed.
• Use the product in the way that is recommended in
this operating manual. This is how to ensure that your
product provides optimum performance.
• Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
WARNING
This power tool generates an electromagnetic field
during operation. This field can impair active or passive
medical implants under certain circumstances. In order
to prevent the risk of serious or deadly injuries, we rec-
ommend that persons with medical implants consult
with their physician and the manufacturer of the medical
implant prior to operating the power tool.
WARNING
In case of extended working periods, the operating per-
sonnel may suffer circulatory disturbances in their
hands (vibration white finger) due to vibrations.
Raynaud's syndrome is a vascular disease that causes
the small blood vessels on the fingers and toes to
cramp in spasms. The affected areas are no longer
supplied with sufficient blood and therefore appear ex-
tremely pale. The frequent use of vibrating products can
cause nerve damage in people whose circulation is im-
paired (e.g. smokers, diabetics).
If you notice unusual adverse effects, stop working im-
mediately and seek medical advice.
ATTENTION
The product is part of the 20V IXES series and may on-
ly be operated with batteries of this series. Batteries
may only be charged with battery chargers of this se-
ries. Observe the manufacturer's instructions.
16 | GB
WARNING
Follow the safety and charging instructions
and correct usage given in the instruction
manual of your 20V IXES Series battery and
charger.
charging process and further information are
provided in this separate manual.
6
Technical data
¼ inch cordless impact
screwdriver
Engine voltage
Idle speeds n
Nominal impact speed
Max. torque
Tool receiver
Suitable for metal screws
Suitable for wood screws
Weight (without battery)
Temperature
• Operation
• Storage
Subject to technical changes!
Noise and vibration
WARNING
Noise can have serious effects on your health. If the
machine noise exceeds 85 dB, please wear suitable
hearing protection for you and persons in the vicinity.
The noise and vibration values have been determined in
accordance with EN 62841-1.
Noise data
Sound pressure L
Measurement uncertainty K
Sound power L
Measurement uncertainty K
Vibration parameters
Vibration a
Measurement uncertainty K
The total vibration emission values specified and the de-
vice emissions values specified have been measured in
accordance with a standardised test procedure and can
be used for comparison of one electric tool with another.
The total noise emission values specified and the total vi-
bration emission values specified can also be used for an
initial estimation of the load.
www.scheppach.com
A
detailed
description
0
pA
pA
wA
pA
h
of
the
C-ID180-X
20 V
0 - 2800 rpm
0 - 3600 rpm
180 Nm
¼ inch
≤ M8
≤ 8 mm Ø
1.3 kg
max. 50°C
-20 – 50°C
5 – 30°C
76.2 dB
3 dB
84.2 dB
3 dB
2
0.571 m/s
2
1.5 m/s