MAINTENANCE
CLEANING THE HEADS
Cassette cover
Pinch roller
Cotton swab
Capstan
Capstan
Record/ Playback head
DEMAGNETIZING THE HEADS
Demagnetizer
® Read the instructions that come withthe demagnetizer carefully on
use.
CLEANING THE CABINET
When the heads, capstans and pinch rollers become dirty, this may
result in muffled, distorted or reduced sound during playback and
may even result in tape jams,
Open the cassette compartment door and remove the cassette cover
and clean with a cotton swab moistened with a commercially sold
head/pinch roller cleaner or alcohol.
@ Wait approximately 10 seconds for the alcohol or cleaning fluid to
dry before using.
lf the heads are used for a long time, the heads will gradually become
magnetized.
When the head becomes magnetized:
® Treble tones may be lost and distortion may result during playback,
# Static distortions may be recorded along with recordings.
@ Distortion
and noise may be recorded
on previously recorded
music tapes.
Any of the above may occur.
Demagnetize the head with a commercially sold head demagnetizer
approximately once every 30 hours of playing time.
Any magnetized metal object brought near the heads may result
in the heads being magnetized also. .
To clean the cabinet or panel, wipe with a soft cloth and a dilute soap
solution.
Then wipe with a dry cloth.
Do not use a chemically treated cleaning cloth, benzine or
paint thinner.
This will cause the cabinet material te change chemically and result
in cracking, peeling, or damage to the finish.
Lubrication with oil may result in damage to the unit.
LE] 17