Salicru SPS.ADVANCE RT2 Manual De Usuario página 48

Idiomas disponibles
  • ES

Idiomas disponibles

use as handles on each side of the UPS, respecting its
mounting orientation.
To install the device in a rack cabinet, it is necessary to
ˆ
have internal lateral guides for use as supports. Alterna-
tively, and upon request, we can supply universal slides for
use as guides, for installation by the user.
Fig. 6. Rack-type mounting in a 19" cabinet.
Mount the guides at the required height, ensuring correct
ˆ
tightening of the fixing screws and appropriate fitting in
the machining, according to each case.
Place the device onto the guides and insert it all the way
ˆ
to the back.
Depending on the device model and weight, and/or
whether it is installed in the upper or lower part of the
cabinet, it is recommended that two people carry out the
installation operations.
Fix the UPS to the cabinet frame using the screws supplied
ˆ
with the handles.
5.1.5.2. Rack-type mounting in a 19" cabinet with
backup extension (battery module).
This section describes a device with one battery module. For
more battery modules, repeat the same procedure for each of
them.
Proceed as follows (see ):
Using the supplied screws, fix the two adapter angles for
ˆ
use as handles on each side of the UPS, respecting its
mounting orientation. Repeat the same procedure for the
battery module.
48
Fig. 7. Rack-type mounting in a 19" cabinet with backup exten-
sion (battery module).
To install each unit, UPS and battery module in a rack
ˆ
cabinet, it is necessary to have internal lateral guides for
use as supports. Alternatively, and upon request, we can
supply universal slides for use as guides, for installation
by the user.
Mount the guides at the required height, ensuring correct
tightening of the fixing screws and appropriate fitting in
the machining, according to each case.
Place the device onto the guides and insert it all the way to
ˆ
the back. Proceed in the same way for the battery module.
Depending on the weight of each unit according to the type
of device and battery module, and/or whether it is installed
in the upper or lower part of the cabinet, it is recommended
that two people carry out the installation operations.
Fix the UPS and the battery module to the cabinet frame
ˆ
by means of the screws supplied with the respective han-
dles.
5.1.5.3. Vertical tower-type mounting.
Take the 4 pieces of plastic supplied with the device and join
them together in twos to obtain two bases.
Place the UPS upright between the two bases at a distance of
70 mm from each end (see Fig. 6).
SALICRU