Possible failure and its solution
3.4
DEFECT
The flame is weak and
orange colour, the pellet
accumulate inside tank
and door window is full
of ash.
The flame turn off and
the stove automatically
blowing out.
Pellet are not introduced.
The stove blowing out
after few min.
Control Pannel doesn't
turn on.
POSSIBLE CAUSE
Insufficient combustion
air.
Too much pellets fall
down in the basket burner
− Pellet tank in empty.
− Pellet are not
introduced.
− The thermostat take part.
− Bad quality Pellet.
− Low Pellet feed.
− Pellet tank is empty.
− Screw Feeder or electric
card are defective.
− Screw feeder is
obstructed.
Exhaus gas has not joint
the necessary temperature.
The stove doesn't receive
electricity.
49/104
IT-GB-FR-ES mod. 514S-514N
SOLUTION
− To clean the combustion basket
and to scrape off the scale to avoid
obstructions to change air. Employ
pellet of good quality..
− To check that the air combustion
circulation is not osbtructed by
ash.
− To check if the air tube or exhaus
fumetube are obstructed.
− To cheack the seal of fire door.
− To call the qualify staff.
− To check the combustion as
described preceding.
− To call the assistance centre to
make the regulations.
− To load pellet tank.
− Read info about not introduction
pellet.
− Let the stove turned off. When the
stove is cold try to start it again.
− To check the regulation from Your
assistance centre. Repeat 1 cycle
of starting.
− To regulate the combustion
through the pellets correction (see
the chapter Combustion
Regulation)
− To require intervention specialist
staff.
− To check the tank and to load it.
− To check the apparatus from
assistance centre and to substitue
with original spare parts.
− To clean the tank and screw
feeder.
− Try to start it again.
− To check the stove plug.
− To check the general switch will
be on 1 position.
− To check and substitue the fuse on
electric card.