If no key is touched within 30 seconds before final confirmation, the emitter
will return to the previous mode of operation.
When the desired temperature is entered confirm with the OK key.
ON will be displayed.
time, it is possible to change the set point temperature during the operation of the function using
the
and
keys.
Once the set time has elapsed, the emitter will automatically return to the last operational mode.
To exit this function at any time, the OK key should be touched. OFF will be displayed.
5.7. Open Windows function
When the Open Windows mode is enabled in the configuration menu the emitter automatically
stops heating when it detects a sudden drop in temperature (4 °C in 20 minutes). This is nor-
mally caused when a window or door is opened to the outside without turning off the emitter.
When the Open Windows mode has activated it is indicated on the display by
a single screen with an open window. To enable the heating again the user
must touch the Standby key. The emitter will then return to the previous
mode of operation.
Note: In installations where this function is activated very frequently, it may
be appropriate to keep it disabled.
* This function is considered by Directive 2009/125/EC regulations and will give the unit
more efficiency during operation.
5.8. Adaptive start control function
When the adaptive start function mode is enabled in the configuration menu, the emitter auto-
matically starts the heating, with a maximum of 2 hours before, to ensure that the next on set-
point is reached efficiently.
The emitter analyses the next two hours, and if there is a set point
higher than the current room temperature within that period, and know-
ing the heating speed of the unit, the software calculates when it needs
to start heating. This calculation is made each 5 minutes.
This function only runs when the emitter is in Program mode. When
Adaptive Start is running a flashing clock icon is displayed next to the thermometer symbol. The
mode will only function on temperature rise e.g., from anti-frost to eco/comfort, or from eco to
comfort.
A73021554
The selected time will remain on the display and count down
until it is finished, and with the standby or sun symbol de-
pending on whether temperature set point or unheated
mode has been selected, as well as the temperature itself in
case of forced heating. Although you cannot change the set
EN